Back to Search
Start Over
Assessment of Non-contrast-enhanced Dixon Water-fat Separation Compressed Sensing Whole-heart Coronary MR Angiography at 3.0 T: A Single-center Experience
- Source :
- Academic Radiology. 29:S82-S90
- Publication Year :
- 2022
- Publisher :
- Elsevier BV, 2022.
-
Abstract
- The clinical utility of Dixon water-fat separation coronary MR angiography (CMRA) with compressed sensing (CS) reconstruction has not been determined in a patient population. This study was designed to evaluate the performance of 3.0 T non-contrast-enhanced Dixon water-fat separation CS whole-heart CMRA sequence in vitro and in vivo.In vitro phantom MRI, we compared key parameters of the SENSE and CS images. And in this prospective in vivo study, from November 2019 to October 2020, 94 participants were recruited for 3.0 T non-contrast-enhanced Dixon water-fat separation CS whole-heart CMRA. The accuracy of CMRA for detecting a ≥ 50% reduction in diameter was determined using X-ray coronary angiography (CA) as the reference method.Compared with SENSE, CS with an appropriate acceleration factor offers both higher SNR/CNR (p0.05) and a shortened acquisition. Fifty-eight patients successfully completed the CMRA and CA. The sensitivity, specificity, positive predictive values, negative predictive values, and accuracy of 3.0 T non-contrast-enhanced Dixon water-fat separation CS whole-heart CMRA according to a patient-based analysis were 96.4%, 66.7%, 73.0%, 95.2% and 81.0%, respectively. The area under the receiver-operator characteristic (ROC) curve (AUC) of 3.0 T non-contrast-enhanced Dixon water-fat separation CS whole-heart CMRA for detecting significant coronary artery stenosis is 0.908, 0.895, and 0.904 in patient-, vessel-, and segment-based analyses respectively.3.0 T non-contrast-enhanced Dixon water-fat separation whole-heart CMRA using appropriate CS is a promising noninvasive and radiation-free technique to detect clinically significant coronary stenosis on patients with suspected CAD.
- Subjects :
- Coronary angiography
Contrast Media
Coronary Angiography
Single Center
Imaging phantom
Magnetic resonance angiography
030218 nuclear medicine & medical imaging
Coronary artery disease
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Radiology, Nuclear Medicine and imaging
Prospective Studies
medicine.diagnostic_test
business.industry
Coronary Stenosis
Mr angiography
Water
medicine.disease
Coronary Vessels
Magnetic Resonance Imaging
Coronary arteries
medicine.anatomical_structure
Compressed sensing
030220 oncology & carcinogenesis
business
Nuclear medicine
Magnetic Resonance Angiography
Subjects
Details
- ISSN :
- 10766332
- Volume :
- 29
- Database :
- OpenAIRE
- Journal :
- Academic Radiology
- Accession number :
- edsair.doi.dedup.....86d40d65c5378a4aee5397069341e86f