Back to Search
Start Over
A pilot randomized controlled trial comparing THUNDERBEAT to the Maryland LigaSure energy device in laparoscopic left colon surgery
- Source :
- Surgical Endoscopy. 36:4265-4274
- Publication Year :
- 2021
- Publisher :
- Springer Science and Business Media LLC, 2021.
-
Abstract
- Background The THUNDERBEAT is a multi-functional energy device which delivers both ultrasonic and bipolar energy, but there are no randomized trials which can provide more rigorous evaluation of the clinical performance of THUNDERBEAT compared to other energy-based devices in colorectal surgery. The aim of this study was to compare the clinical performance of THUNDERBEAT energy device to Maryland LigaSure in patients undergoing left laparoscopic colectomy. Methods Prospective randomized trial with two groups: Group 1 THUNDERBEAT and Group 2 LigaSure in a single university hospital. 60 Subjects, male and female, of age 18 years and above undergoing left colectomy for cancer or diverticulitis were included. The primary outcome was dissection time to specimen removal (DTSR) measured in minutes from the start of colon mobilization to specimen removal from the abdominal cavity. Versatility (composite of five variables) was measured by a score system from 1 to 5 (1 being worst and 5 the best), and adjusted/weighted by coefficient of importance with distribution of the importance as follow: hemostasis 0.275, sealing 0.275, cutting 0.2, dissection 0.15, and tissue manipulation 0.1. Other variables were: dryness of surgical field, intraoperative and postoperative complications, and mortality. Follow-up time was 30 days. Results 60 Patients completed surgery, 31 in Group 1 and 29 in Group 2. There was no difference in the DTSR between the groups, 91 min vs. 77 min (p = 0.214). THUNDERBEAT showed significantly higher score in dissecting and tissue manipulation in segment 3 (omental dissection), and in overall versatility score (p = 0.007) as well as versatility score in Segment 2 (retroperitoneal dissection p = 0.040) and Segment 3 (p = 0.040). No other differences were noted between the groups. Conclusions Both energy devices can be employed effectively and safely in dividing soft tissue and sealing mesenteric blood vessels during laparoscopic left colon surgery, with THUNDERBEAT demonstrating some advantages over LigaSure during omental dissection and tissue manipulation. ClinicalTrial.gov # NCT02628093.
- Subjects :
- Male
medicine.medical_specialty
Adolescent
Colon
Pilot Projects
Abdominal cavity
Dissection (medical)
law.invention
Randomized controlled trial
law
Humans
Medicine
Prospective Studies
Colectomy
Maryland
business.industry
Soft tissue
Diverticulitis
medicine.disease
Energy device
Colorectal surgery
Surgery
medicine.anatomical_structure
Hemostasis
Female
Laparoscopy
business
Subjects
Details
- ISSN :
- 14322218 and 09302794
- Volume :
- 36
- Database :
- OpenAIRE
- Journal :
- Surgical Endoscopy
- Accession number :
- edsair.doi.dedup.....8640e1c0a08864a7a2c9beeb6f3230ea