Back to Search
Start Over
Non-invasive measurement of pulse pressure variation using a finger-cuff method in obese patients having laparoscopic bariatric surgery
- Source :
- Journal of Clinical Monitoring and Computing
- Publication Year :
- 2020
- Publisher :
- Springer Science and Business Media LLC, 2020.
-
Abstract
- Pulse pressure variation (PPV) is a dynamic cardiac preload variable used to predict fluid responsiveness. PPV can be measured non-invasively using innovative finger-cuff systems allowing for continuous arterial pressure waveform recording, e.g., the Nexfin system [BMEYE B.V., Amsterdam, The Netherlands; now Clearsight (Edwards Lifesciences, Irvine, CA, USA)] (PPVFinger). However, the agreement between PPVFinger and PPV derived from an arterial catheter (PPVART) in obese patients having laparoscopic bariatric surgery is unknown. We compared PPVFinger and PPVART at 6 time points in 60 obese patients having laparoscopic bariatric surgery in a secondary analysis of a prospective method comparison study. We used Bland–Altman analysis to assess absolute agreement between PPVFinger and PPVART. The predictive agreement for fluid responsiveness between PPVFinger and PPVART was evaluated across three PPV categories (PPV 13%) as concordance rate of paired measurements and Cohen’s kappa. The overall mean of the differences between PPVFinger and PPVART was 0.5 ± 4.6% (95%-LoA − 8.6 to 9.6%) and the overall predictive agreement was 72.4% with a Cohen’s kappa of 0.53. The mean of the differences was − 0.7 ± 3.8% (95%-LoA − 8.1 to 6.7%) without pneumoperitoneum in horizontal position and 1.1 ± 4.8% (95%-LoA − 8.4 to 10.5%) during pneumoperitoneum in reverse-Trendelenburg position. The absolute agreement and predictive agreement between PPVFinger and PPVART are moderate in obese patients having laparoscopic bariatric surgery.
- Subjects :
- medicine.medical_specialty
genetic structures
Concordance
Fluid responsiveness
Bariatric Surgery
Blood Pressure
Health Informatics
Nexfin
Critical Care and Intensive Care Medicine
03 medical and health sciences
0302 clinical medicine
Pneumoperitoneum
Hemodynamic monitoring
030202 anesthesiology
medicine
Humans
Arterial Pressure
Obesity
Original Research
business.industry
Dynamic preload variable
030208 emergency & critical care medicine
Arterial catheter
medicine.disease
Clearsight
Pulse pressure
Surgery
Preload
Anesthesiology and Pain Medicine
Cuff
Laparoscopy
business
Kappa
Subjects
Details
- ISSN :
- 15732614 and 13871307
- Volume :
- 35
- Database :
- OpenAIRE
- Journal :
- Journal of Clinical Monitoring and Computing
- Accession number :
- edsair.doi.dedup.....854f2f4072dc11b32359b5ec94af1ff5
- Full Text :
- https://doi.org/10.1007/s10877-020-00614-8