Updated outcomes from the TRANSFIX study to evaluate endovascular repair of blunt thoracic aortic injuries with the Zenith Alpha thoracic device
- Source :
- Journal of vascular surgery. 71(6)
- Publication Year :
- 2018
-
Abstract
- Objective The purpose of this study was to report the updated results of a prospective, multicenter, nonrandomized, single-arm investigational device exemption study conducted at 17 sites in the United States to assess safety and effectiveness of the Zenith Alpha thoracic endovascular graft (Cook Medical, Bloomington, Ind) for treatment of blunt thoracic aortic injury (BTAI). Methods The primary safety end point was 30-day all-cause mortality and aortic injury-related mortality. The primary effectiveness end point was 30-day device success. Additional outcomes evaluated included major adverse events and imaging findings including aortic injury healing, graft patency, and device integrity as analyzed by the core laboratory on follow-up computed tomography imaging through 5 years. Results A total of 50 patients with BTAI were enrolled in the TRANSFIX study between January 2013 and May 2014. Mean follow-up was 21 months (range, 0.6-35 months). The 30-day mortality was 2% (n = 1), and it was unrelated to the aortic repair or study device. Five deaths occurred after 30 days, and one was considered procedure related. Freedom from all-cause and BTAI-related mortality was 89.3% and 97.6%, respectively, at 2 years. Aortic injury healing was noted in 96% at 2 years. An incidental finding of thrombus formation within the stent graft, most commonly at the distal aspect of the study device, occurred in 15 patients (30%; 12 by core laboratory, 3 by site) and was confirmed in 13 patients (26%). None of these patients were noted to have clinical sequelae on most recent follow-up. Conclusions The updated results from the TRANSFIX study continue to show low rates of aortic injury-related mortality and major adverse events during follow-up. However, findings of in-graft thrombus have resulted in the manufacturer's voluntary removal of the BTAI indication for this device. Caution should be exercised in appropriate and accurate device sizing and planning (eg, limiting graft oversizing) as well as in regular, lifelong follow-up evaluation.
- Subjects :
- medicine.medical_specialty
Time Factors
Thoracic Injuries
medicine.medical_treatment
Aorta, Thoracic
Investigational device exemption
030204 cardiovascular system & hematology
Prosthesis Design
Wounds, Nonpenetrating
03 medical and health sciences
Blood Vessel Prosthesis Implantation
0302 clinical medicine
Blunt
Risk Factors
medicine.artery
medicine
Humans
030212 general & internal medicine
Prospective Studies
Thrombus
Adverse effect
Transfix
Aorta
business.industry
Endovascular Procedures
Stent
Vascular System Injuries
medicine.disease
United States
Surgery
Blood Vessel Prosthesis
Treatment Outcome
Stents
Core laboratory
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 10976809
- Volume :
- 71
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Journal of vascular surgery
- Accession number :
- edsair.doi.dedup.....84caa21c84e81062f64dbe11416f6fab