Back to Search Start Over

Unintentional staining of lens posterior capsule with trypan blue during extracapsular cataract extraction: case report

Authors :
José Ricardo Carvalho Lima Rehder
Frederico F. Marques
Daniela Meira Villano Marques
Fábio Medaglia Soccol
Universidade Federal de São Paulo (UNIFESP)
Faculdade de Medicina do ABC Departamento de Oftalmologia
Source :
Repositório Institucional da UNIFESP, Universidade Federal de São Paulo (UNIFESP), instacron:UNIFESP, Arquivos Brasileiros de Oftalmologia, Vol 69, Iss 1, Pp 111-113 (2006)
Publication Year :
2006
Publisher :
Conselho Brasileiro de Oftalmologia, 2006.

Abstract

Relato de complicação relacionada ao uso do azul de tripano 0,1% ocorrida ao corar a cápsula anterior do cristalino em facectomia extracapsular com implante de lente intra-ocular. O corante foi injetado sob alta pressão utilizando a técnica de bolha de ar ocasionando a migração deste através da zônula e conseqüente perda do reflexo vermelho no peroperatório dificultando os passos subseqüentes à extração da catarata e comprometendo temporariamente a acuidade visual no pós-operatório. Tendo como objetivo evitar esta complicação, os autores descrevem ainda, o uso da Técnica de bolha de ar modificada no qual o viscoelástico dispersivo é injetado no espaço iridolenticular 360° para compor uma barreira de proteção. Report of a complication related to the use of 0.1% trypan blue during capsular staining of the anterior crystalline lens capsule in an extracapsular cataract extraction with intraocular lens implantation. The capsular dye was injected using an air-bubble technique, inadvertently, it was done using high pressure dispersing the dye through the zonules leading to a complete losts of red reflex, the following steps of the procedure becoming more difficult after the cataract extraction and causing a temporary disturbance of visual acuity in the postoperative period. In order to avoid this complication, the authors also describe the use of Modified air-bubble technique where dispersive viscoelastic is placed into the iridolenticular space 360° to create a protection barrier. Universidade Federal de São Paulo (UNIFESP) Faculdade de Medicina do ABC Departamento de Oftalmologia Universidade Federal de São Paulo, EPM, São Paulo, Brazil SciELO

Details

Language :
Portuguese
Database :
OpenAIRE
Journal :
Repositório Institucional da UNIFESP, Universidade Federal de São Paulo (UNIFESP), instacron:UNIFESP, Arquivos Brasileiros de Oftalmologia, Vol 69, Iss 1, Pp 111-113 (2006)
Accession number :
edsair.doi.dedup.....84051d6b5e771f92ac6907e9d4616b1d