Back to Search
Start Over
Comparative Analysis of Cutting Forces, Torques, and Vibration in Drilling of Bovine, Porcine, and Artificial Femur Bone with Considerations for Robot Effector Stiffness
- Source :
- Journal of Healthcare Engineering, Vol 2020 (2020), Journal of Healthcare Engineering
- Publication Year :
- 2020
- Publisher :
- Hindawi Limited, 2020.
-
Abstract
- Bone drilling is known as one of the most sensitive milling processes in biomedical engineering field. Fracture behavior of this cortical bone during drilling has attracted the attention of many researchers; however, there are still impending concerns such as necrosis, tool breakage, and microcracks due to high cutting forces, torques, and high vibration while drilling. This paper presents a comparative analysis of the cutting forces, torques, and vibration resulted on different bone samples (bovine, porcine, and artificial femur) using a 6dof Robot arm effector with considerations of its stiffness effects. Experiments were conducted on two spindle speeds of 1000 and 1500 rpm with a drill bit diameter of 2.5 mm and 6 mm depth of cut. The results obtained from the specimens were processed and analyzed using MATLAB R2015b and Visio 2000 software; these results were then compared with a prior test using manual and conventional drilling methods. The results obtained show that there is a significant drop in the average values of maximum drilling force for all the bone specimens when the spindle speed changes from 1000 rev/min to 1500 rev/min, with a drop from (20.07 to 12.34 N), approximately 23.85% for bovine, (11.25 to 8.14 N) with 16.03% for porcine, and (5.62 to 3.86 N) with 33.99% for artificial femur. The maximum average values of torque also decrease from 41.2 to 24.2 N·mm (bovine), 37.0 to 21.6 N·mm (porcine), and 13.6 to 6.7 N·mm (artificial femur), respectively. At an increase in the spindle speed, the vibration amplitude on all the bone samples also increases considerably. The variation in drilling force, torque, and vibration in our result also confirm that the stiffness of the robot effector joint has negative effect on the bone precision during drilling process.
- Subjects :
- 0209 industrial biotechnology
Medicine (General)
Materials science
Article Subject
Swine
0206 medical engineering
Biomedical Engineering
Health Informatics
02 engineering and technology
Vibration
Bone and Bones
020901 industrial engineering & automation
R5-920
medicine
Medical technology
Drill bit
Torque
Animals
Femur
R855-855.5
Stiffness
Drilling
Robotics
020601 biomedical engineering
medicine.anatomical_structure
Surgery
Cortical bone
Cattle
medicine.symptom
Robotic arm
Biotechnology
Biomedical engineering
Research Article
Subjects
Details
- Language :
- English
- ISSN :
- 20402309 and 20402295
- Volume :
- 2020
- Database :
- OpenAIRE
- Journal :
- Journal of Healthcare Engineering
- Accession number :
- edsair.doi.dedup.....838a38751493df3e5dd730d85c320c8e