Back to Search
Start Over
Imaging the Tear Film: A Comparison Between the Subjective Keeler Tearscope-Plus™ and the Objective Oculus® Keratograph 5M and LipiView® Interferometer
- Source :
- Current Eye Research. 43:155-162
- Publication Year :
- 2017
- Publisher :
- Informa UK Limited, 2017.
-
Abstract
- To compare non-invasive break-up time (NIBUT) when measured with the Tearscope-Plus™ and the Oculus® Keratograph 5M, and to compare lipid layer thicknesses (LLT) when measured with the Tearscope-Plus™ and the LipiView®. This study also set out to establish the repeatability of these methods.The following measurements were taken from both eyes of 24 participants on two occasions: non-invasive keratograph break-up time using the Oculus® (NIKBUT-1 and NIKBUT-average), NIBUT using the Tearscope-Plus™, and LLT using the LipiView® (minimum, maximum, and average) and Tearscope-Plus™. The Tearscope-Plus™ grades were converted to nanometers.There were no significant differences between eyes (Tearscope-Plus™ NIBUT: p = 0.52; NIKBUT-1: p = 0.052; NIKBUT-average: p = 0.73; Tearscope-Plus™ LLT: p = 0.13; LipiView® average, maximum, or minimum: p = 0.68, 0.39 and 0.50, respectively) or days (Tearscope-Plus™ NIBUT: p = 0.32; NIKBUT-1: p = 0.65; NIKBUT-average: p = 0.54; Tearscope-Plus™ LLT: p = 0.26; LipiView® average, maximum, or minimum: p = 0.20, 0.09, and 0.10, respectively). LLT was significantly greater with the Tearscope-Plus™ (80.4 ± 34.0 nm) compared with the LipiView® average (56.3 ± 16.1 nm, p = 0.007), minimum (50.1 ± 15.8 nm, p 0.001) but not maximum (67.2 ± 19.6 nm, p = 0.55). NIBUT was significantly greater with the Tearscope-Plus™ (15.9 ± 10.7 seconds) compared to the NIKBUT-1 (8.2 ± 3.5 seconds, p = 0.006) but not NIKBUT-average (10.9 ± 3.9 seconds, p = 0.08).The Tearscope-Plus™ is not interchangeable with either the Oculus® K5M measurement of tear stability (NIKBUT-1) or the LipiView® maximum and minimum lipid thickness.
- Subjects :
- Adult
Male
medicine.medical_specialty
Adolescent
Oculus
Diagnostic Techniques, Ophthalmological
Young Adult
03 medical and health sciences
Cellular and Molecular Neuroscience
0302 clinical medicine
Optics
Ophthalmology
medicine
Humans
Mathematics
business.industry
Reproducibility of Results
Repeatability
Lipids
Healthy Volunteers
Sensory Systems
Interferometry
Tear break up time
Tears
030221 ophthalmology & optometry
Female
business
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 14602202 and 02713683
- Volume :
- 43
- Database :
- OpenAIRE
- Journal :
- Current Eye Research
- Accession number :