Back to Search
Start Over
Network latency and long‐distance robotic telestenting: Exploring the potential impact of network delays on telestenting performance
- Source :
- Catheterization and Cardiovascular Interventions. 95:914-919
- Publication Year :
- 2019
- Publisher :
- Wiley, 2019.
-
Abstract
- Objective This study evaluated the impact of network latency on telestenting performance. Background The feasibility of long-distance robotic telestenting was recently demonstrated, yet the impact of network performance on telestenting remains unknown. Methods Ex vivo and in vivo telestenting models were constructed by connecting a robotic drive over a wired network to a robotic control system up to 103 miles away. During consecutive attempts to robotically wire a coronary artery, investigators randomly added signal latencies from 0 to 1,000 ms. Outcomes included wiring success, wiring time (time to advance wire to preselected target landmark), and perceived latency score (5 = imperceptible; 4 = noticeable but minor; 3 = noticeable; 2 = noticeable and major; 1 = unacceptable). Results Wiring success was achieved in 95 of 95 attempts in the ex vivo model and in 57 of 57 attempts in vivo. No significant difference in wiring time was observed across added latencies from 0 to 1,000 ms in the ex vivo (p = .64) or in vivo (p = .40) models. Compared to an added latency of 0 ms, perceived latency scores were not significantly different for added latencies of 150 and 250 ms (p = NS for both), but were significantly lower for latencies ≥400 ms (p Conclusions Added latencies up to 250 ms were not associated with perceived latency, but latencies ≥400 ms were perceptible. Based on these findings, future telestenting studies should utilize networks with latencies ≤250 ms if perceived latency is to be avoided.
- Subjects :
- medicine.medical_specialty
Time Factors
Sus scrofa
Coronary Artery Disease
030204 cardiovascular system & hematology
Audiology
Manikins
Computer Communication Networks
03 medical and health sciences
Percutaneous Coronary Intervention
0302 clinical medicine
medicine
Animals
Humans
Radiology, Nuclear Medicine and imaging
Network performance
030212 general & internal medicine
Latency (engineering)
Potential impact
Robotic control
business.industry
Remote Consultation
Significant difference
Robotics
General Medicine
Therapy, Computer-Assisted
Models, Animal
Feasibility Studies
Female
Stents
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 1522726X and 15221946
- Volume :
- 95
- Database :
- OpenAIRE
- Journal :
- Catheterization and Cardiovascular Interventions
- Accession number :
- edsair.doi.dedup.....82a2986536407293e72d2689f818ae39
- Full Text :
- https://doi.org/10.1002/ccd.28425