Back to Search
Start Over
Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
- Source :
- Journal of Contemporary Brachytherapy, Journal of Contemporary Brachytherapy, Vol 9, Iss 2, Pp 139-145 (2017)
- Publication Year :
- 2017
- Publisher :
- Termedia Sp. z.o.o., 2017.
-
Abstract
- Purpose: To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy. Material and methods : Delineation of LC and CTV was done by five radiation oncologists on planning computed tomography (CT) scans of 20 patients with intraoperative interstitial breast implant. Cavity visualization index (CVI), four-point index ranging from (0 = poor) to (3 = excellent) was created and assigned by observers for each patient. In total, 200 contours for all observers and 100 treatment plans were evaluated. Spatial concordance (conformity index, CI common , and CIgen), average shift in the center of mass (COM), and ratio of maximum and minimum volumes (V max /V min ) of LC and CTV were quantified among all observers and statistically analyzed. Variation in active dwell positions (0.5 cm step) for each catheter, total reference air kerma (TRAK), volume enclosed by prescription isodose (V100%) among observers and its spatial concordance were analyzed. Results : The mean ± SD CI common of LC and CTV was 0.54 ± 0.09, and 0.58 ± 0.08, respectively. Conformity index tends to increase, shift in COM and V max /V min decrease significantly (p < 0.05), as CVI increased. Out of total 309 catheters, 29.8% catheters had no change, 29.8% and 17.5% catheters had variations of 1 and 2 dwell positions (0.5 cm and 1 cm), respectively. 9.3% catheters shown variations ≥ 10 dwell positions (5 cm). The mean ± SD CI common of V100% was 0.75 ± 0.11. The mean observed V max /V min of prescription isodose and TRAK was 1.18 (range, 1.03 to 1.56) and 1.11 (range, 1.03 to 1.35), respectively. Conclusions : Interobserver variability in delineation of target volume was found to be significantly related to CVI. Smaller variability was observed with excellent visualization of LC. Interobserver variations showed dosimetric impact on irradiation of breast tissue volume with prescription dose.
- Subjects :
- interobserver variation
medicine.medical_specialty
medicine.medical_treatment
Brachytherapy
Planning target volume
lcsh:Medicine
APBI
030218 nuclear medicine & medical imaging
law.invention
03 medical and health sciences
Kerma
breast cancer
0302 clinical medicine
Breast cancer
law
medicine
Radiology, Nuclear Medicine and imaging
Original Paper
business.industry
lcsh:R
Lumpectomy
Partial Breast Irradiation
medicine.disease
Catheter
Oncology
030220 oncology & carcinogenesis
Breast implant
Radiology
cavity visualization
Nuclear medicine
business
Subjects
Details
- ISSN :
- 1689832X
- Volume :
- 2
- Database :
- OpenAIRE
- Journal :
- Journal of Contemporary Brachytherapy
- Accession number :
- edsair.doi.dedup.....825c338d778a9e8e9f752ebb19c040f6