Back to Search
Start Over
An on-site dosimetry audit for high-energy electron beams
- Source :
- Physics and Imaging in Radiation Oncology, Physics and Imaging in Radiation Oncology, Vol 5, Iss, Pp 44-51 (2018)
- Publication Year :
- 2018
- Publisher :
- Elsevier, 2018.
-
Abstract
- Background and purpose: External dosimetry audits are powerful quality assurance instruments for radiotherapy. The aim of this study was to implement an electron dosimetry audit based on a contemporary code of practice within the requirements for calibration laboratories performing proficiency tests. This involved the determination of suitable acceptance criteria based on thorough uncertainty analyses. Materials and methods: Subject of the audit was the determination of absorbed dose to water, Dw, and the beam quality specifier, R50,dos. Fifteen electron beams were measured in four institutes according to the Belgian-Dutch code of practice for high-energy electron beams. The expanded uncertainty (k = 2) for the Dw values was 3.6% for a Roos chamber calibrated in 60Co and 3.2% for a Roos chamber cross-calibrated against a Farmer chamber. The expanded uncertainty for the beam quality specifier, R50,dos, was 0.14 cm. The audit acceptance levels were based on the expanded uncertainties for the comparison results and estimated to be 2.4%. Results: The audit was implemented and validated successfully. All Dw audit results were satisfactory with differences in Dw values mostly smaller than 0.5% and always smaller than 1%. Except for one, differences in R50,dos were smaller than 0.2 cm and always smaller than 0.3 cm. Conclusions: An electron dosimetry audit based on absorbed dose to water and present-day requirements for calibration laboratories performing proficiency tests was successfully implemented. It proved international traceability of the participants value with an uncertainty better than 3.6% (k = 2). Keywords: Absorbed dose to water, Audit, Code of practice, Dosimetry, Electron beam, Radiation therapy
- Subjects :
- lcsh:Medical physics. Medical radiology. Nuclear medicine
Electron beam
medicine.medical_specialty
Traceability
Computer science
lcsh:R895-920
Audit
lcsh:RC254-282
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Acceptance testing
Dosimetry
Calibration
medicine
Radiology, Nuclear Medicine and imaging
Medical physics
Original Research Article
Radiation
business.industry
Absorbed dose to water
lcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
Radiation therapy
030220 oncology & carcinogenesis
Absorbed dose
Code of practice
business
Quality assurance
Subjects
Details
- Language :
- English
- ISSN :
- 24056316
- Volume :
- 5
- Database :
- OpenAIRE
- Journal :
- Physics and Imaging in Radiation Oncology
- Accession number :
- edsair.doi.dedup.....824bb6a03a0651a703ea531dd480fd88