Back to Search
Start Over
Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws
- Source :
- International Orthopaedics, Vol. 35, No 7 (2011) pp. 957-63
- Publication Year :
- 2010
- Publisher :
- Springer-Verlag, 2010.
-
Abstract
- Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at ten years with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d'Aubigné and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120 months (± 7.3 months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At ten years, the cup survivorship was 98.8% (95% CI 97.4-99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9 mm. The Morscher acetabular replacement cup provides excellent results at ten years. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very good.
- Subjects :
- musculoskeletal diseases
Adult
Male
medicine.medical_specialty
Arthroplasty, Replacement, Hip
Health Status
Aseptic loosening
Osteolysis/etiology
Kaplan-Meier Estimate
Osteolysis
Prosthesis Design
Young Adult
Patient satisfaction
Postoperative Complications
Medicine
Humans
Orthopedics and Sports Medicine
Prospective Studies
Cementation
Hip Joint/physiopathology/radiography/surgery
Aged
Aged, 80 and over
Original Paper
ddc:617
business.industry
Acetabulum
Middle Aged
Ucla score
equipment and supplies
Surgery
Radiography
surgical procedures, operative
Treatment Outcome
Acetabular component
Harris Hip Score
Patient Satisfaction
Orthopedic surgery
Female
Hip Joint
Hip Prosthesis
Acetabulum/radiography/surgery
business
Arthroplasty, Replacement, Hip/adverse effects/instrumentation/methods
Total hip arthroplasty
Follow-Up Studies
Subjects
Details
- Language :
- English
- ISSN :
- 03412695
- Database :
- OpenAIRE
- Journal :
- International Orthopaedics, Vol. 35, No 7 (2011) pp. 957-63
- Accession number :
- edsair.doi.dedup.....81bf71cd361e7c8a15b5581462e4db6a