Back to Search Start Over

An Automated High-Throughput Enterovirus D68 Microneutralization Assay Platform

Authors :
Eric E. Rhoden
Bernardo A. Mainou
Jennifer L. Konopka-Anstadt
M. Steven Oberste
Source :
SSRN Electronic Journal.
Publication Year :
2022
Publisher :
Elsevier BV, 2022.

Abstract

Virus neutralization assays, widely used to detect and quantify antibodies induced by virus infection, are considered the gold standard for enterovirus serology testing. Conventional microneutralization assays have been used to assess enterovirus D68 (EV-D68) seroprevalence. While manual or automated 96-well assays are valuable, higher-density assays that increase throughput provide the opportunity to more efficiently screen large, population-based serology collections, as well as to test sample sets against multiple virus strains on the same plate or within the same run. Here, automation was implemented for bulk reagent dispensing, serial dilutions, and luminescence measurement to develop a 384-well enterovirus microneutralization assay that increases overall testing throughput, maintains the reproducibility of the standard 96-well assay, and reduces sample volume usage. EV-D68 strains Fermon, 14-18953, and 18-23087 were used to evaluate the automated 384-well microneutralization assay and compare to the conventional 96-well assay. Sensitivity and specificity were evaluated using pooled human sera and positive and negative control antisera. The Lower Limit of quantitation (LLOQ) was the same as for the 96-well assay and coefficients of variations (CV) of 7.35 %, 5.97 %, and 2.85 % for the three EV-D68 strains respectively, were well below the typical goal of ≤ 20 % CV for accuracy. Z-factor analysis yielded results of 0.694, 0.638, and 0.852, for the three EV-D68 strains respectively, indicating a high level of precision, reliability, and robustness. Intra-assay (7.25 %) and inter-assay (7.12 %) variability were well below 20 % CV. Moreover, the 96-well and 384-well versions of the assay were highly concordant, with a 0.955 correlation coefficient in titers obtained for 50 sera tested. Validation of this automated 384-well microneutralization will support its use in large serology screens assessing the presence of EV-D68 neutralizing antibodies in human populations.

Details

ISSN :
15565068
Database :
OpenAIRE
Journal :
SSRN Electronic Journal
Accession number :
edsair.doi.dedup.....818f7f7822e66000d67d07a7979f69b1