Back to Search
Start Over
A serial fluoroscopy-guided thrombolytic therapy of a mechanical tricuspid prosthetic valve thrombosis with low-dose and ultra-slow infusion of tissue-type plasminogen activator
- Source :
- Türk Kardiyoloji Derneği Arşivi, Vol 42, Iss 5, Pp 478-481 (2014)
- Publication Year :
- 2014
-
Abstract
- Prosthetic valve thrombosis is a life-threatening complication that is seen most commonly in patients with left-sided prosthetic valves. However, mechanical tricuspid valves carry the highest risk of thrombosis of any cardiac valve. Thrombolysis has been performed successfully in right-sided prosthetic valve thrombosis and has been recommended as the first-line treatment in these patients. Although two-dimensional and real-time three-dimensional transesophageal echocardiography are the gold standard imaging modalities for the diagnosis of prosthetic valve thrombosis, right-sided prosthetic valves may not be evaluated precisely. This is a serious problem during the follow-up of patients who receive thrombolytic therapy for tricuspid valve thrombosis. Fluoroscopy is an alternative noninvasive imaging method that provides valuable information about leaflet motion and may be used for such cases with restricted leaflets. Herein, we report a case of tricuspid valve thrombosis who was managed with low-dose (25 mg) and ultra-slow (25 hours) infusion of tissue-type plasminogen activator under the guidance of serial fluoroscopy.
- Subjects :
- Adult
medicine.medical_specialty
lcsh:Internal medicine
lcsh:Diseases of the circulatory (Cardiovascular) system
medicine.medical_treatment
lcsh:Medicine
Drug Administration Schedule
Diagnosis, Differential
Fibrinolytic Agents
medicine
Fluoroscopy
echocardiography
Humans
Thrombolytic Therapy
Prosthetic Valve Thrombosis
lcsh:RC31-1245
Infusions, Intravenous
Tricuspid valve
medicine.diagnostic_test
business.industry
lcsh:R
Thrombosis
Thrombolysis
fluoroscopy
prosthetic valve thrombosis
tricuspid valve
thrombolytic therapy
medicine.disease
Surgery
medicine.anatomical_structure
lcsh:RC666-701
Heart Valve Prosthesis
Tissue Plasminogen Activator
Tissue type
Female
Radiology
transesophageal
Tricuspid Valve
Cardiology and Cardiovascular Medicine
Complication
business
Plasminogen activator
Echocardiography, Transesophageal
Subjects
Details
- ISSN :
- 10165169
- Volume :
- 42
- Issue :
- 5
- Database :
- OpenAIRE
- Journal :
- Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir
- Accession number :
- edsair.doi.dedup.....81181542d88c0bc0acd6bde362e2e7a6