Back to Search Start Over

Practical approach to method verification in plasma and validation in cerebrospinal fluid under accreditation using a flexible scope in molecular virology: setting up the HIV, HBV and HCV Aptima™ Quant Dx assays

Authors :
Françoise Lunel-Fabiani
Cong T. Tran
Alexandra Ducancelle
Hélène Le Guillou-Guillemette
Adeline Pivert
Caroline Lefeuvre
Hémodynamique, Interaction Fibrose et Invasivité tumorales Hépatiques (HIFIH)
Université d'Angers (UA)
Source :
Clinical Chemistry and Laboratory Medicine, Clinical Chemistry and Laboratory Medicine, De Gruyter, 2020, 58 (2), pp.251-260. ⟨10.1515/cclm-2019-0502⟩
Publication Year :
2020
Publisher :
HAL CCSD, 2020.

Abstract

BackgroundOur laboratory obtained the ISO 15189 accreditation for the plasmatic HIV-1, HBV and HCV viral load (VL) using the m2000 RealTime™ system, which was recently changed for the platform Panther®. Here, we discuss a strategy for performing method validation/verification very quickly.MethodsWe performed the mandatory (repeatability, internal quality assessment [IQA], measurement uncertainty [MU]) and optional technical verifications for CE/IVD assays using the flexible scope range A. We also performed the mandatory assays for the validation of HIV-1 VL in the cerebrospinal fluid (CSF) using the flexible scope range B. The change was checked by following up on the turnaround time (TAT).ResultsThe coefficient of variation (CV%) for repeatability and IQA complied with the limit of 0.25 log. The MU results ranged from 0.04 to 0.25 log copies or IU/mL. The comparisons of methods showed excellent correlations (R2 = 0.96 for the three parameters) but a delayed centrifugation on HCV VL showed variations of up to 2 log IU/mL. An excellent linearity for HIV-1 in the CSF was obtained from 1.5 to 5 log copies/mL with R2 = 0.99. The TAT increased (84%–98%) in routine usage.ConclusionsThe three Aptima assays are well suited for routine laboratory use and can be integrated within less than 2 weeks in accordance with flexible scope range A. Our data allows us to confidently perform HIV-1 VL in CSF following flexible scope range B. Finally, we provide an organizational guide for flexible scope management in molecular virology within a short time frame.

Details

Language :
English
ISSN :
14346621 and 14374331
Database :
OpenAIRE
Journal :
Clinical Chemistry and Laboratory Medicine, Clinical Chemistry and Laboratory Medicine, De Gruyter, 2020, 58 (2), pp.251-260. ⟨10.1515/cclm-2019-0502⟩
Accession number :
edsair.doi.dedup.....80ca5f7fa60e698bfd77407b738b9eea
Full Text :
https://doi.org/10.1515/cclm-2019-0502⟩