Back to Search
Start Over
Hemodynamic assessment of Perceval sutureless bioprosthesis by dobutamine stress echocardiography
- Publication Year :
- 2018
- Publisher :
- WILEY, 2018.
-
Abstract
- Objectives: The aim of this study was to evaluate the hemodynamic performance of a sutureless bioprosthesis under high workload at mid‐term follow‐up. Methods: Thirty‐two patients who underwent isolated aortic valve replacement with a Perceval sutureless bioprosthesis with a minimum follow‐up of 1 year were enrolled in this study. S size prosthesis was deployed in 10 patients (31.3%), M size in 9 (28.1%), L size in 8 (25%) and XL size in 5 (15.6%). Effective orifice area (EOA), EOA index (EOAi), and transvalvular gradients were assessed at rest and during dobutamine stress echocardiography (DSE) a median of 19.5 months after surgery. Results: Dobutamine stress echocardiography (DSE) significantly increased heart rate, stroke volume, ejection fraction, and transvalvular gradients (peak gradient, 24.0 ± 7.6 vs 38.7 ± 13.6 mm Hg, P < .001; mean gradient, 12.6 ± 4.2 vs 19.8 ± 8.3, P < .001). When compared to baseline, estimated valve areas significantly increased at follow‐up (EOA, 1.48 ± 0.46 vs 2.06 ± 0.67, P < .001; EOAi, 0.84 ± 0.26 vs 1.17 ± 0.37, P < .001). Mean percentage increase in EOAi was 40.3% ± 28.0%. S size prostheses had the highest increase in EOA1, but the difference was not significant (S 46.0% ± 27.5% vs M 45.4% ± 34.5% vs L 32.7% ± 26.4% vs XL 32.1% ± 20.5%, P = .66). Severe patient‐prosthesis mismatch (EOAi ≤ 0.65 cm²/m²) was present at rest in 8 patients (25%), but only in one patient (3.1%) during DSE. Conclusions: The Perceval sutureless bioprosthesis demonstrated good hemodynamics at rest and under high workload. The significant increase in EOAi during DSE suggests the potential advantages of Perceval sutureless bioprostheses in case of small aortic annulus or when patient‐prosthesis mismatch is anticipated.
- Subjects :
- Male
medicine.medical_specialty
aortic valve prosthesis
Dobutamine stress echocardiography
medicine.medical_treatment
Hemodynamics
030204 cardiovascular system & hematology
Stress
Prosthesis
03 medical and health sciences
0302 clinical medicine
Postoperative Complications
Aortic valve replacement
Internal medicine
dobutamine stress echocardiography
Medicine
Humans
Radiology, Nuclear Medicine and imaging
aortic valve replacement
Cardiac skeleton
aortic valve prosthetis
Aged
ta3126
Bioprosthesis
Ejection fraction
business.industry
Effective orifice area
Stroke volume
sutureless
Echocardiography, Stress
Female
Follow-Up Studies
Heart Valves
Middle Aged
Sutureless Surgical Procedures
Heart Valve Prosthesis
medicine.disease
aortic valve prosthesi
suturele
030228 respiratory system
Echocardiography
Cardiology
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....800fc7d6c58db5d8f675ad2bb0957574