Back to Search
Start Over
Assessment of platelet function on the routine coagulation analyzer Sysmex CS-2000i
- Source :
- Platelets, Platelets, Taylor & Francis, 2018, 29 (1), pp.95-97. ⟨10.1080/09537104.2017.1353683⟩, Platelets, 2018, 29 (1), pp.95-97. ⟨10.1080/09537104.2017.1353683⟩
- Publication Year :
- 2018
- Publisher :
- HAL CCSD, 2018.
-
Abstract
- International audience; Background: Light transmission aggregometry (LTA) is considered as the gold standard for testing platelet function in the setting of both platelet disorders suspicion and response to antiplatelet therapy evaluation. LTA requires however specialized equipment, substantial blood sample volumes, is technically challenging and time-consuming.Aim: To evaluate an automated platelet aggregation method performed on a routine coagulation analyzer Sysmex CS-2000i. Methods: 46 patients presenting a bleeding syndrome and 62 patients with acute coronary syndrome receiving dual antiplatelet therapy were studied in total. Platelet aggregations were performed on CS-2000i equipped with a dedicated software and on APACT-4004 (Elitech, France) as the reference instrument. Aggregation was measured by monitoring the changes in light absorbance occurring in response to ADP 2.5, 5 and 10µM, collagen 3.3 µg/mL, epinephrin 10µM, ristocetin 1.25 mg/mL and arachidonic acid 0.5 mg/mL in platelet rich plasma (PRP). PRP were tested simultaneously on both CS-2000i and APACT-4004 devices. Platelet stirred speed were 800 rpm for both instruments.Results: Significant correlations were observed between CS-2000i and LTA after all stimulations (p< 0.001). Patients presenting a bleeding syndrome had similar aggregation profiles with both methods. A single patient presented a severe platelet disorder (Glanzmann Thrombasthenia) and its PRP showed defective aggregation in response to all agonists except ristocetin with both instruments. Finally, the inter-agreement rates for CS-2000i and APACT-4004 to detect low responders to thienopyridines or aspirine were strong (weighted kappa> 0.70).Conclusion: Platelet aggregation on the routine coagulation analyzer CS-2000i is an easily accessible, handy, reliable, standardized, and rapid tool to assess platelet function which allows to skirt most of the LTA limitations.
- Subjects :
- Blood Platelets
Spectrum analyzer
Acute coronary syndrome
medicine.medical_specialty
Pathology
Light absorbance
Platelet Aggregation
Platelet Function Tests
[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/Imaging
Platelet disorder
Urology
030204 cardiovascular system & hematology
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
medicine
Humans
Platelet
Ristocetin
business.industry
Reproducibility of Results
[SDV.MHEP.HEM]Life Sciences [q-bio]/Human health and pathology/Hematology
Hematology
General Medicine
medicine.disease
3. Good health
chemistry
Coagulation
030220 oncology & carcinogenesis
Platelet-rich plasma
Blood Coagulation Tests
Blood Platelet Disorders
business
Biomarkers
Platelet Aggregation Inhibitors
Subjects
Details
- Language :
- English
- ISSN :
- 09537104 and 13691635
- Database :
- OpenAIRE
- Journal :
- Platelets, Platelets, Taylor & Francis, 2018, 29 (1), pp.95-97. ⟨10.1080/09537104.2017.1353683⟩, Platelets, 2018, 29 (1), pp.95-97. ⟨10.1080/09537104.2017.1353683⟩
- Accession number :
- edsair.doi.dedup.....7f79020417c06442af048704771b3712