Back to Search Start Over

Collimated prompt gamma TOF measurements with multi-slit multi-detector configurations

Authors :
C. La Tessa
M.-H. Richard
Marco Pinto
J. Krimmer
Etienne Testa
V. Reithinger
Denis Dauvergne
George Dedes
Jean Michel Létang
M. Chevallier
M. De Rydt
Christoph Schuy
Julie Constanzo
Nicolas Freud
Ilaria Rinaldi
R. Pleskac
Cédric Ray
P. Henriquet
F. Roellinghoff
M. Testa
Institut de Physique Nucléaire de Lyon (IPNL)
Centre National de la Recherche Scientifique (CNRS)-Université Claude Bernard Lyon 1 (UCBL)
Université de Lyon-Université de Lyon-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)
Imagerie Tomographique et Radiothérapie
Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (CREATIS)
Université Jean Monnet [Saint-Étienne] (UJM)-Hospices Civils de Lyon (HCL)-Institut National des Sciences Appliquées de Lyon (INSA Lyon)
Institut National des Sciences Appliquées (INSA)-Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université de Lyon-Université Claude Bernard Lyon 1 (UCBL)
Université de Lyon-Centre National de la Recherche Scientifique (CNRS)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Jean Monnet [Saint-Étienne] (UJM)-Hospices Civils de Lyon (HCL)-Institut National des Sciences Appliquées de Lyon (INSA Lyon)
Université de Lyon-Centre National de la Recherche Scientifique (CNRS)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Biophysics Department [Darmstadt]
Helmholtz Centre for Heavy Ion Research (GSI)
Heidelberg Ion Beam Therapy Center - HIT
Heidelberg University Clinic
Source :
Journal of Instrumentation, Journal of Instrumentation, IOP Publishing, 2015, 10, in press. ⟨10.1088/1748-0221/10/01/P01011⟩
Publication Year :
2015
Publisher :
BRISTOL, 2015.

Abstract

International audience; Longitudinal prompt-gamma ray profiles have been measured with a multi-slit multi-detector configuration at a 75 MeV/u 13C beam and with a PMMA target. Selections in time-of-flight and energy have been applied in order to discriminate prompt-gamma rays produced in the target from background events. The ion ranges which have been extracted from each individual detector module agree amongst each other and are consistent with theoretical expectations. In a separate dedicated experiment with 200 MeV/u 12C ions the fraction of inter-detector scattering has been determined to be on the 10%-level via a combination of experimental results and simulations. At the same experiment different collimator configurations have been tested and the shielding properties of tungsten and lead for prompt-gamma rays have been measured.

Details

Language :
English
ISSN :
17480221
Database :
OpenAIRE
Journal :
Journal of Instrumentation, Journal of Instrumentation, IOP Publishing, 2015, 10, in press. ⟨10.1088/1748-0221/10/01/P01011⟩
Accession number :
edsair.doi.dedup.....7f535257a9681cc0c31bff1ddc1b242f