Twenty years outcomes in a single center experience after endovascular aneurysm repair with unibody endograft and anatomical fixation
- Source :
- The Journal of cardiovascular surgery. 61(6)
- Publication Year :
- 2019
-
Abstract
- BaCKground: To assess the long-term safety and effectiveness of endovascular aneurysm repair (evar) treatment with unibody endograft deployed on aortic bifurcation (anatomical fixation). MeThods: a retrospective, observational, single-center study of patients treated from 1999 to 2002 with unibody bifurcated endograft. follow-up protocol required clinical and doppler-ultrasound at 1 and 6 months and annually thereafter, computed tomography angiography at 1-, 6- and 12-months and then every year. Primary endpoints included technical and treatment success, survival and freedom from late evar failure; secondary endpoints were freedom from late open conversion (loC), freedom from late re-interventions and endoleaks. resulTs: seventy-three patients, mean age of 73±6 years were enrolled. Median follow-up was 6±0.5 years. Technical success was 98.6% (n.=71/73; causes of failure: 1 open conversion and 1 type ib endoleak). a treatment success of 96% (n.=69/72) was recorded due to endoleaks (n.=2; 1 type ia and 1 type ib) and limb occlusion (n.=1). survival at 1, 5, 10, 15 and 18 years was 90%, 58%, 40%, 32% and 23% respectively. one aneurysm-related death for infection of the endograft was registered. evar failure was 14% (n.=10/71). Three loC were recorded and freedom from reinterventions at 1, 5, 10 and 18 years was 99%, 91%, 86% and 86%. fourteen endoleaks were recorded: ia (n.=6; 42.8%), ia+ib (n.=1; 7.1%), ib (n.=2; 14.2%) and ii (n.=5; 35.6%). four endoleaks were observed, 9 endovascular correction and 1 loC were required. endoleaks free survival of 90% at 1-year and 75% at the end of the study. aneurysm sac shrinkage was observed in 79% (n.=56/71). CONCLUSIONS: This small, retrospective cohort of anatomically fixed EVAR demonstrated long-term safety and effectiveness. The design of the unibody graft did not substantially change and newer generation should guarantee the same performance.
- Subjects :
- Male
Time Factors
Databases, Factual
Endoleak
medicine.medical_treatment
030204 cardiovascular system & hematology
Single Center
Endovascular aneurysm repair
Aortic aneurysm
0302 clinical medicine
Retrospective Studie
Computed tomography angiography
Aged, 80 and over
medicine.diagnostic_test
Endovascular Procedures
General Medicine
Middle Aged
Abdominal
endoleak
Prostheses
Endovascular procedures
aortic aneurysm
Implants
Aged
Aortic Aneurysm, Abdominal
Blood Vessel Prosthesis Implantation
Female
Humans
Italy
Prosthesis Design
Prosthesis Failure
Prosthesis-Related Infections
Retrospective Studies
Treatment Outcome
Blood Vessel Prosthesis
medicine.anatomical_structure
Cardiology and Cardiovascular Medicine
Human
medicine.medical_specialty
Time Factor
03 medical and health sciences
Aneurysm
Blood vessel prosthesis
Prosthese
medicine
Prosthesis-Related Infection
Endovascular Procedure
business.industry
Implant
Retrospective cohort study
Aortic bifurcation
medicine.disease
Surgery
030228 respiratory system
business
Subjects
Details
- ISSN :
- 1827191X
- Volume :
- 61
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- The Journal of cardiovascular surgery
- Accession number :
- edsair.doi.dedup.....7e8b091408a739d65236a68e289bda61