Back to Search
Start Over
How to reduce 'double-firing'-induced scope damage by investigating the relationship between laser fiber core degradation and fiber jacket burn?
- Source :
- PLoS ONE, PLoS ONE, Vol 15, Iss 5, p e0233135 (2020)
- Publication Year :
- 2020
-
Abstract
- Purpose 'Double-firing effect' in which laser firing occurs in the fiber tip and its proximal part is caused by different breakdown rates between fiber jackets and cores. This study investigated a new safe distance concept to prevent scope damage by analyzing the breakdown of the laser fiber jacket and cores. Methods Laser fibers were fixed in a benchtop simulation model. The fiber tip was in contact with uniform phantom stones and submerged in saline. Four different energy settings (1.0 or 2.0J x 10Hz or 30Hz) and two different fiber sizes (200 μm and 365 μm) were tested. After three minutes of use at each energy setting, the length of fiber shortening and jacket burn were measured. The fibers were stripped to measure the length of core degradation. Results Mean degradation lengths were 4.2 to 7.8 mm. There was no statistical difference in the mean lengths of fiber core degradation and jacket burn. However, core degradation was longer than the jacket burn in half of the samples. The mean difference in lengths between core degradation and jacket burn was 0.49 ± 0.90 mm. Lengths of core degradation and the jacket burn were longer at the setting of high-power energy and 200 μm fiber - 2J with 30 Hz. Conclusion To reduce 'double-firing'-induced damage, the authors recommend that laser fiber should be cut 1.0 mm longer than visible jacket burn at high-power settings after 3-min continuous fragmentation. After cutting the fiber, the laser should be checked whether 'double-firing' is no more seen.
- Subjects :
- Optical fiber
Medical Doctors
Health Care Providers
030232 urology & nephrology
Statistical difference
law.invention
0302 clinical medicine
law
Medicine and Health Sciences
Medical Personnel
Composite material
Materials
Optical Fibers
Oxalates
Multidisciplinary
respiratory system
Fibers
Chemistry
Professions
Optical Equipment
030220 oncology & carcinogenesis
Physical Sciences
Medicine
Engineering and Technology
Anatomy
Plastic Surgery and Reconstructive Techniques
Research Article
Materials science
Science
Materials Science
Equipment
Surgical and Invasive Medical Procedures
Mean difference
03 medical and health sciences
Physicians
Laser fiber
Computer Simulation
Surgeons
Lasers
Chemical Compounds
Biology and Life Sciences
Renal System
Models, Theoretical
Laser
Health Care
Surgical Repair
People and Places
Population Groupings
Ureter
Subjects
Details
- ISSN :
- 19326203
- Volume :
- 15
- Issue :
- 5
- Database :
- OpenAIRE
- Journal :
- PloS one
- Accession number :
- edsair.doi.dedup.....7cf76f526b6692d9d5f54219b6d73d49