Back to Search Start Over

Is Patient‐Specific Instrumentation Accurate and Necessary for Open‐Wedge High Tibial Osteotomy? A Meta‐Analysis

Authors :
Ran Pang
Zhaohui Jiang
Chunlei Xu
Wei Shi
Xinglong Zhang
Xin Wan
Daniel Bahat
Hui Li
Fedor Senatov
Inna Bulygina
Hu Wang
Huafeng Zhang
Zhijun Li
Source :
Orthopaedic Surgery. 15:413-422
Publication Year :
2022
Publisher :
Wiley, 2022.

Abstract

The purpose of this meta-analysis was to identify if patient-specific instrumentation (PSI) could increase the accuracy of the correction in high tibial osteotomy (HTO) and to explore the assessment indices and the necessity of using a PSI in HTO. A systematic search was carried out using online databases. A total of 466 patients were included in 11 papers that matched the inclusion criteria. To evaluate the accuracy of PSI-assisted HTO, the weight bearing line ratio (WBL%), hip-knee-ankle angle (HKA), mechanical medial proximal tibial angle (mMPTA), and posterior tibial slope angle (PTSA) were measured preoperatively and postoperatively and compared to the designed target values. Statistical analysis was performed after strict data extraction with Review Manager (version 5.4). Significant differences were detected in WBL% (MD = -36.41; 95% CI: -42.30 to -30.53; p 0.00001), HKA (MD = -9.95; 95% CI: -11.65 to -8.25; p 0.00001), and mMPTA (MD = -8.40; 95% CI:-10.27 to -6.53; p 0.00001) but not in PTSA (MD = 0.34; 95% CI: -0.59 to 1.27; p = 0.47) between preoperative and postoperative measurements. There was no significant difference between the designed target values and the postoperative correction values of HKA (MD = 0.14; 95% CI: -0.19 to 0.47; p = 0.41) or mMPTA (MD = 0.11; 95% CI -0.34 to 0.55; p = 0.64). The data show that 3D-based planning of PSI for HTO is both accurate and safe. WBL%, HKA, and mMPTA were the optimal evaluation indicators of coronal plane correction. Sagittal correction is best evaluated by the PTSA. The present study reports that PSI is accurate but not necessary in typical HTO.

Details

ISSN :
17577861 and 17577853
Volume :
15
Database :
OpenAIRE
Journal :
Orthopaedic Surgery
Accession number :
edsair.doi.dedup.....7cd61c78795ea60a4c5fab8b585e79c4