Back to Search
Start Over
Rapid antigen test had up to 98% sensitivity and 100% specificity for detecting COVID-19 in persons with mild symptoms
- Source :
- EClinicalMedicine
- Publication Year :
- 2021
- Publisher :
- American College of Physicians, 2021.
-
Abstract
- Background RT-qPCR is the reference test for identification of active SARS-CoV-2 infection, but is associated with diagnostic delay. Antigen detection assays can generate results within 20 min and outside of laboratory settings. Yet, their diagnostic test performance in real life settings has not been determined. Methods The diagnostic value of the Panbio™ COVID-19 Ag Rapid Test (Abbott), was determined in comparison to RT-qPCR (Seegene Allplex) in community-dwelling mildly symptomatic subjects in a medium (Utrecht, the Netherlands) and high endemic area (Aruba), using two concurrently obtained nasopharyngeal swabs. Findings: 1367 and 208 subjects were enrolled in Utrecht and Aruba, respectively. SARS-CoV-2 prevalence, based on RT-qPCR, was 10.2% (n = 139) and 30.3% (n = 63) in Utrecht and Aruba respectively. Specificity of the Panbio™ COVID-19 Ag Rapid Test was 100% (95%CI: 99.7–100%) in both settings. Test sensitivity was 72.6% (95%CI: 64.5–79.9%) in the Netherlands and 81.0% (95% CI: 69.0–89.8%) in Aruba. Probability of false negative results was associated with RT-qPCR Ct-values, but not with duration of symptoms. Restricting RT-qPCR test positivity to Ct-values
- Subjects :
- 2019-20 coronavirus outbreak
medicine.medical_specialty
Coronavirus disease 2019 (COVID-19)
business.industry
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)
General Medicine
Gastroenterology
Mild symptoms
Antigen
Rapid antigen test
Internal medicine
Internal Medicine
medicine
business
Research Paper
Subjects
Details
- ISSN :
- 15393704 and 00034819
- Volume :
- 174
- Database :
- OpenAIRE
- Journal :
- Annals of Internal Medicine
- Accession number :
- edsair.doi.dedup.....7b83e499d7ab0db92e8a57c31a18f283