Back to Search
Start Over
Feasibility of ventricular volumetry by cardiovascular MRI to assess cardiac function in the fetal sheep
- Source :
- The Journal of Physiology. 598:2557-2573
- Publication Year :
- 2020
- Publisher :
- Wiley, 2020.
-
Abstract
- KEY POINTS The application of fetal cardiovascular magnetic resonance imaging (CMR) to assess fetal cardiovascular physiology and cardiac function through the quantification of ventricular volumes has previously been investigated, but the approach has not yet been fully validated. Ventricular output measurements calculated from heart rate and stroke volumes (SV) of the right and left ventricles measured by ventricular volumetry (VV) exhibited a high level of agreement with phase-contrast (PC) blood flow measurements in the main pulmonary artery and ascending aorta, respectively. Ejection fraction of the right ventricle, which is lower than that of the left ventricle in postnatal subjects, was similar to the left ventricular ejection fraction in the fetus; probably due to the different loading conditions present in the fetal circulation. This study provides evidence to support the reliability of VV in the sheep fetus, providing evidence for its use in animal models of human diseases affecting the fetal circulation. ABSTRACT The application of ventricular volumetry (VV) by cardiovascular magnetic resonance imaging (CMR) in the fetus remains challenging due to the small size of the fetal heart and high heart rate. The reliability of this technique in utero has not yet been established. The aim of this study was to assess the feasibility and reliability of VV in a fetal sheep model of human pregnancy. Right and left ventricular outputs by stroke volume (SV) measured using VV were compared with 2D phase-contrast (PC) CMR measurements of blood flow in the main pulmonary artery (MPA) and ascending aorta (AAo). At 124-140 days (d) gestation, singleton bearing Merino ewes underwent CMR under general anaesthesia using fetal femoral artery catheters, implanted at 109-117d, to trigger cine steady state free precession acquisitions of ventricular short-axis stacks. The short-axis cine stacks were segmented at end-systole and end-diastole, yielding right and left ventricular SV, ejection fraction, and cardiac outputs (SV × heart rate). PC cine acquisitions of MPA and AAo were analysed to measure blood flow, which served as comparators for the right and left cardiac outputs by VV. There was good correlation and agreement between VV and PC measures of ventricular outputs with no significant bias (r2 = 0.926; P
- Subjects :
- 0301 basic medicine
Cardiac function curve
medicine.medical_specialty
Physiology
Heart Ventricles
cardiovascular magnetic resonance imaging
Pulmonary Artery
Ventricular Function, Left
03 medical and health sciences
0302 clinical medicine
Pregnancy
Cardiac magnetic resonance imaging
Internal medicine
medicine.artery
Ascending aorta
Animals
Medicine
cardiovascular diseases
Sheep
Ejection fraction
medicine.diagnostic_test
business.industry
Reproducibility of Results
Stroke Volume
Stroke volume
Blood flow
Magnetic Resonance Imaging
030104 developmental biology
medicine.anatomical_structure
Fetal circulation
Ventricle
fetal circulation
cardiovascular system
Cardiology
Feasibility Studies
Female
cardiac function
business
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 14697793 and 00223751
- Volume :
- 598
- Database :
- OpenAIRE
- Journal :
- The Journal of Physiology
- Accession number :
- edsair.doi.dedup.....7a665e1adfdd320bb26a45041c576760
- Full Text :
- https://doi.org/10.1113/jp279054