Back to Search Start Over

SARAF Equipped Cavity Test Stand (ECTS) at CEA

Authors :
Piquet, Olivier
Boulch, Cyril
Braud, Didier
Carbonnier, Pol
Chirpaz-Cerbat, Didier
Ferrand, Guillaume
Gohier, Francis
Gouit, Florian
Guiho, Patrice
Joannem, Tom
Maurice, Luc
Monnereau, Gilles
Plaisant, Thomas
Plouin, Juliette
Pérolat, Alain
Sahuquet, Patrick
Solenne, Nicolas
Institut de Recherches sur les lois Fondamentales de l'Univers (IRFU)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay
Publication Year :
2019
Publisher :
HAL CCSD, 2019.

Abstract

CEA is committed to delivering a Medium Energy Beam Transfer line and a Super Conducting Linac (SCL) for SARAF accelerator in order to accelerate 5mA beam of either protons from 1.3MeV to 35MeV or deuterons from 2.6 MeV to 40.1MeV. The SCL consists in 4 cryomodules separated by warm section housing beam diagnostics. The two first identical cryomodules hosts respectively 6 and 7 half-wave resonator (HWR) low beta (0.091) cavities 176MHz. In order to test the cavity with its tuner and coupler and validate some design consideration, the Equipped Cavity Test Stand (ECTS) has been designed and will be presented.<br />Proceedings of the 10th Int. Particle Accelerator Conf., IPAC2019, Melbourne, Australia