Back to Search
Start Over
Identifiability of tissue material parameters from uniaxial tests using multi-start optimization
- Source :
- Acta Biomater
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- Determining tissue biomechanical material properties from mechanical test data is frequently required in a variety of applications. However, the validity of the resulting constitutive model parameters is the subject of debate in the field. Parameter optimization in tissue mechanics often comes down to the “identifiability” or “uniqueness” of constitutive model parameters; however, despite advances in formulating complex constitutive relations and many classic and creative curve-fitting approaches, there is currently no accessible framework to study the identifiability of tissue material parameters. Our objective was to assess the identifiability of material parameters for established constitutive models of fiber-reinforced soft tissues, biomaterials, and tissue-engineered constructs and establish a generalizable procedure for other applications. To do so, we generated synthetic experimental data by simulating uniaxial tension and compression tests, commonly used in biomechanics. We then fit this data using a multi-start optimization technique based on the nonlinear least-squares method with multiple initial parameter guesses. We considered tendon and sclera as example tissues, using constitutive models that describe these fiber-reinforced tissues. We demonstrated that not all the model parameters of these constitutive models were identifiable from uniaxial mechanical tests, despite achieving virtually identical fits to the stress-stretch response. We further show that when the lateral strain was considered as an additional fitting criterion, more parameters are identifiable, but some remain unidentified. This work provides a practical approach for addressing parameter identifiability in tissue mechanics.
- Subjects :
- Computer science
0206 medical engineering
Constitutive equation
Biomedical Engineering
02 engineering and technology
Models, Biological
Biochemistry
Article
Tendons
Biomaterials
Applied mathematics
Uniqueness
Molecular Biology
Lateral strain
Experimental data
General Medicine
021001 nanoscience & nanotechnology
020601 biomedical engineering
Biomechanical Phenomena
Nonlinear system
Identifiability
Stress, Mechanical
0210 nano-technology
Material properties
Biotechnology
Test data
Subjects
Details
- ISSN :
- 17427061
- Volume :
- 123
- Database :
- OpenAIRE
- Journal :
- Acta Biomaterialia
- Accession number :
- edsair.doi.dedup.....79f43523cb0740051cec886268153e9c