Back to Search Start Over

Implant-free iliac crest bone graft procedure shows anatomic remodelling without redislocation in recurrent anterior shoulder instability after short-term follow-up

Authors :
Rudolf Maximilian Kinsky
Sandra Boesmueller
Greta Lorenz
Rainer Mittermayr
Christian Fialka
Marta Berchtold
Micha Komjati
Source :
Archives of Orthopaedic and Trauma Surgery. 142:1047-1054
Publication Year :
2021
Publisher :
Springer Science and Business Media LLC, 2021.

Abstract

With the help of a J-shaped bicortical iliac crest bone graft, the morphology of the glenoid can be augmented without having to use screws to achieve glenohumeral stability. The aim of this retrospective clinical study was to evaluate the clinical stability and function of the shoulder joint as well as the radiological remodelling process and arthropathic outcomes following the J-bone graft technique. 34 patients with recurrent shoulder dislocations and bony glenoid defects were treated with the J-bone graft technique between 2010 and 2018 at our level-I trauma centre. 15 patients (18 shoulders) could be recruited for the study. Pain levels, ASES, UCLA, SST, DASH, Rowe and WOSI Scores were collected using questionnaires. In 13 patients (16 shoulders) the Constant Score, ROM, CT with 3D reconstruction of the glenoid to assess the graft remodelling and X-rays were performed additionally. None of the patients suffered subluxations or recurrent dislocations during the follow-up period. The overall complication rate was 11%. The evaluation using objective and subjective shoulder function scores yielded good-to-excellent results. Radiological assessment at follow-up showed a low rate of moderate-to-severe arthritis (12%) and a high rate of shoulders without any signs of arthritic degeneration (53%). The CT scans all revealed an almost complete restoration of the glenoid with none of the grafts being resorbed. A rise in the average glenoid circumference and glenoid area could be demonstrated between preoperative measurements (81.6 and 82.4%, respectively) and follow-up measurements (104 and 102.5%, respectively). The results of this study show a successful stabilisation of the shoulder joint and a low complication rate following the J-bone graft technique. Remodelling of the bone graft could be demonstrated, which in turn led to an almost perfect glenoid surface area of 100%.

Details

ISSN :
14343916
Volume :
142
Database :
OpenAIRE
Journal :
Archives of Orthopaedic and Trauma Surgery
Accession number :
edsair.doi.dedup.....7932e1b34113c4777d0dbd8bb7ecfbe0
Full Text :
https://doi.org/10.1007/s00402-021-03777-4