Back to Search
Start Over
A comparative analysis of intensity-based 2D–3D registration for intraoperative use in pedicle screw insertion surgeries
- Source :
- International Journal of Computer Assisted Radiology and Surgery. 14:1725-1739
- Publication Year :
- 2019
- Publisher :
- Springer Science and Business Media LLC, 2019.
-
Abstract
- Although multiple algorithms have been reported that focus on improving the accuracy of 2D–3D registration techniques, there has been relatively little attention paid to quantifying their capture range. In this paper, we analyze the capture range for a number of variant formulations of the 2D–3D registration problem in the context of pedicle screw insertion surgery. We tested twelve 2D–3D registration techniques for capture range under different clinically realistic conditions. A registration was considered as successful if its error was less than 2 mm and 2° in 95% of the cases. We assessed the sensitivity of capture range to a variety of clinically realistic parameters including: X-ray contrast, number and configuration of X-rays, presence or absence of implants in the image, inter-subject variability, intervertebral motion and single-level vs multi-level registration. Gradient correlation + Powell optimizer had the widest capture range and the least sensitivity to X-ray contrast. The combination of 4 AP + lateral X-rays had the widest capture range (725 mm2). The presence of implant projections significantly reduced the registration capture range (up to 84%). Different spine shapes resulted in minor variations in registration capture range (SD 78 mm2). Intervertebral angulations of less than 1.5° had modest effects on the capture range. This paper assessed capture range of a number of variants of intensity-based 2D–3D registration algorithms in clinically realistic situations (for the use in pedicle screw insertion surgery). We conclude that a registration approach based on the gradient correlation similarity and the Powell’s optimization algorithm, using a minimum of two C-arm images, is likely sufficiently robust for the proposed application.
- Subjects :
- Similarity (geometry)
Computer science
media_common.quotation_subject
0206 medical engineering
Biomedical Engineering
Health Informatics
Context (language use)
02 engineering and technology
030218 nuclear medicine & medical imaging
03 medical and health sciences
Imaging, Three-Dimensional
0302 clinical medicine
Pedicle Screws
Range (statistics)
Humans
Contrast (vision)
Radiology, Nuclear Medicine and imaging
Computer vision
Sensitivity (control systems)
Pedicle screw
media_common
business.industry
General Medicine
020601 biomedical engineering
Computer Graphics and Computer-Aided Design
Spine
Computer Science Applications
Intensity (physics)
Surgery, Computer-Assisted
Surgery
Computer Vision and Pattern Recognition
Artificial intelligence
Tomography, X-Ray Computed
Focus (optics)
business
Algorithms
Subjects
Details
- ISSN :
- 18616429 and 18616410
- Volume :
- 14
- Database :
- OpenAIRE
- Journal :
- International Journal of Computer Assisted Radiology and Surgery
- Accession number :
- edsair.doi.dedup.....7683fec6410ec72a662090f4abe2d1fb