Comparison of interface contact profiles of a new minimum contact locking compression plate and the limited contact dynamic compression plate
- Source :
- International Orthopaedics. 34:715-718
- Publication Year :
- 2009
- Publisher :
- Springer Science and Business Media LLC, 2009.
-
Abstract
- In this study, we investigated whether or not a new minimum contact locking compression plate (MC-LCP) can provide advantages over the limited contact dynamic compression plate (LC-DCP) in the context of interface contact area and force. Six matched pairs of cadaveric bones were used for each of three bone types of the humerus, radius and ulna. For each bone type, one of two bone plates was fixed to either of two matched cadaveric bones at the middle of the diaphysis. The interface contact area and force of the plate fixed to three types of human cadaveric bones were evaluated using Fuji prescale pressure sensitive film. Data were quantitated using computer-assisted image analysis. Results showed that the average force between the MC-LCP and humerus or radius was about half of that of the LC-DCP. And the average force between the MC-LCP and ulna was one third less than that of the LC-DCP. Meanwhile, the interface contact area between the MC-LCP and humerus or radius was also about half of that of the LC-DCP, and the interface contact area between the MC-LCP and ulna was less than one third of that of the LC-DCP. These results indicate that the MC-LCP has lower interface contact area and lower average force than that of the LC-DCP. Thus, the MC-LCP system may be a good alternate to treat forearm diaphyseal fractures.
- Subjects :
- Adult
Male
Ulna
Context (language use)
Prosthesis Design
Bone and Bones
Weight-Bearing
Fracture Fixation, Internal
Bone plate
Fracture fixation
Cadaver
Image Processing, Computer-Assisted
Pressure
medicine
Humans
Orthopedics and Sports Medicine
Humerus
Original Paper
business.industry
Anatomy
Middle Aged
Compression (physics)
Equipment Failure Analysis
Radius
Diaphysis
medicine.anatomical_structure
Female
Surgery
Contact area
business
Bone Plates
Biomedical engineering
Subjects
Details
- ISSN :
- 14325195 and 03412695
- Volume :
- 34
- Database :
- OpenAIRE
- Journal :
- International Orthopaedics
- Accession number :
- edsair.doi.dedup.....7577a12341a0cf97781237f49c1a805f
- Full Text :
- https://doi.org/10.1007/s00264-009-0836-8