Back to Search
Start Over
Phase-shift cavity ring-down spectroscopy to determine absolute line intensities
- Source :
- Chemical Physics Letters, 400(4-6), 320-325. Elsevier
- Publication Year :
- 2004
- Publisher :
- Elsevier, 2004.
-
Abstract
- Cavity ring-down detection techniques can sensitively determine frequency-dependent absorption cross-sections of gasses. However, so-called line-width problems and amplified spontaneous emission of the laser light source lowers the technique’s quantitative accuracy. Using phase-shift cavity ring-down spectroscopy (PSCRD), we measured absolute line intensities of the spin-forbidden transitions in the b 1 Σ g + ( ν ′ = 0 ) ← X 3 Σ g - ( ν ″ = 0 ) band of molecular oxygen. Our results were within 4% of values obtained from the HITRAN database, demonstrating the accuracy of PSCRD, when corrected for amplified spontaneous emission. Its high sensitivity (2 × 10−8 cm−1), simplicity and high duty cycle make PSCRD a powerful diagnostic technique.
Details
- Language :
- English
- ISSN :
- 00092614
- Volume :
- 400
- Issue :
- 4-6
- Database :
- OpenAIRE
- Journal :
- Chemical Physics Letters
- Accession number :