Back to Search
Start Over
Reproducibility of Vessel Density, Fractal Dimension, and Foveal Avascular Zone Using 7 Different Optical Coherence Tomography Angiography Devices
- Source :
- American Journal of Ophthalmology. 186:25-31
- Publication Year :
- 2018
- Publisher :
- Elsevier BV, 2018.
-
Abstract
- Purpose To evaluate the reproducibility of parafoveal microvascular anatomy of 7 different optical coherence tomography angiography (OCT-A) devices by comparing vessel density (VD), fractal dimension (FD), and foveal avascular zone (FAZ) of superficial and deep capillary plexus in healthy volunteers. Design Reliability analysis. Methods Consecutive healthy volunteers presenting at the Eye Clinic, Department of Biomedical and Clinical Sciences, Luigi Sacco Hospital, University of Milan in the same clinic visit were imaged by 7 different OCT-A devices: Optovue RTVue XR Avanti (Optovue, Inc, Fremont, California, USA), prototype Spectralis OCT-A (Spectralis; Heidelberg Engineering, Heidelberg, Germany), AngioPlex (Cirrus 5000 HD-OCT; Carl Zeiss Meditec, Inc, Dublin, California, USA), prototype PlexElite (Carl Zeiss Meditec), RS-3000 Advance (Nidek, Gamagori, Japan), OCT-HS100 (Canon, Tokyo, Japan), and Revo NX (Optopol Technology SA, Zawiercie, Poland). OCT-A examinations were performed using a 3 × 3 mm volume scan pattern centered on the fovea. Mean VD, FD, and FAZ values between the instruments were compared. Results The 7 different devices presented measurements with different mean values, with only a limited number of comparisons not significantly different between the instruments. Moreover, Bland-Altman analysis revealed that the limits of agreement for all the comparisons were not acceptable. Regression analysis was used in the development of tables to compare various devices, despite which large standard errors were found for both intercepts and slope conversion values. Conclusions Our results suggest that the comparison between instruments is nearly impossible and the set of measurements from the various instruments are not interchangeable regarding VD, FD, and FAZ for both the superficial and deep capillary plexus.
- Subjects :
- Adult
Male
0301 basic medicine
Fovea Centralis
medicine.medical_specialty
Capillary plexus
genetic structures
Fundus Oculi
Fractal dimension
03 medical and health sciences
Imaging, Three-Dimensional
0302 clinical medicine
Vessel density
Ophthalmology
medicine
Humans
Fluorescein Angiography
Retrospective Studies
Reproducibility
business.industry
Limits of agreement
Reproducibility of Results
Retinal Vessels
Equipment Design
Optical coherence tomography angiography
Foveal avascular zone
Healthy Volunteers
eye diseases
Clinic visit
Fractals
030104 developmental biology
Microvessels
030221 ophthalmology & optometry
Female
sense organs
business
Tomography, Optical Coherence
Subjects
Details
- ISSN :
- 00029394
- Volume :
- 186
- Database :
- OpenAIRE
- Journal :
- American Journal of Ophthalmology
- Accession number :
- edsair.doi.dedup.....732dbe8f665109fa39c8237f05a954a1
- Full Text :
- https://doi.org/10.1016/j.ajo.2017.11.011