Back to Search
Start Over
Impact of Stent-Graft Oversizing on Gutter Areas after Chimney Graft Repair for Complex Abdominal Aortic Aneurysms
- Source :
- Annals of vascular surgery. 51
- Publication Year :
- 2016
-
Abstract
- Background The aim of this retrospective study was to examine the impact of graft oversizing on gutter area and stent compression in chimney graft (CG) for complex abdominal aortic aneurysm (CAAA) repair. The influence of stent-graft oversizing on type Ia endoleaks and bridging stent occlusion rates was also examined. Methods Preoperative and postoperative computed tomographic angiography scans of patients requiring CGs for CAAA between June 2009 and April 2013 in our institution were analyzed. Two groups were identified: proximal oversizing of the stent-graft component 25% (group 2). Relative gutter areas were calculated and compared between both groups. Incidence of target vessel stent compression, target vessel occlusions, and type Ia endoleaks was also analyzed. Results Of 39 patients treated with CG during the study period, 23 fulfilled the selection criteria for analysis. Group 1 included 10 patients and group 2 included 13 patients (mean oversizing: 18.4 ± 4.9% and 34.5 ± 6% respectively). Relative gutter areas were significantly higher in group 1 when compared with group 2 (6.1 ± 2.1% vs. 4.2 ± 3.2%, P = 0.03). No stent compression and no target vessel occlusion occurred in either groups. There was no statistical difference in type Ia endoleak in both groups (group 1 n = 0, group 2 n = 2; P = 0.48). Conclusions In our study, a >25% stent-graft oversizing reduced the gutter area without modifying the bridging stent patency. However, no benefit in terms of type Ia endoleak was observed.
- Subjects :
- medicine.medical_specialty
Time Factors
Endoleak
Computed Tomography Angiography
medicine.medical_treatment
Statistical difference
030204 cardiovascular system & hematology
030230 surgery
Prosthesis Design
Aortography
Stent occlusion
03 medical and health sciences
Blood Vessel Prosthesis Implantation
0302 clinical medicine
Risk Factors
Occlusion
Medicine
Humans
Vascular Patency
Retrospective Studies
business.industry
Endovascular Procedures
Chimney graft
Graft Occlusion, Vascular
Stent
Retrospective cohort study
General Medicine
medicine.disease
Abdominal aortic aneurysm
Surgery
Blood Vessel Prosthesis
Computed tomographic angiography
Treatment Outcome
Stents
France
Cardiology and Cardiovascular Medicine
business
Aortic Aneurysm, Abdominal
Preliminary Data
Subjects
Details
- ISSN :
- 16155947
- Volume :
- 51
- Database :
- OpenAIRE
- Journal :
- Annals of vascular surgery
- Accession number :
- edsair.doi.dedup.....72861ea5166926594c19b092b5eb5d24