The Effect of Magnetic Field on the Position of HTS Leads and the Cooler in the Services Tower of the MICE Focusing Magnet

Authors :
Martin A. Green
J.H. Cobb
P. Lau
Shiming Yang
W. Lau
T.W. Bradshaw
D.E. Baynham
Holger Witte
Source :
Green, M.A.; Yang, S.Q.; Cobb, J.; Lau, P.; Lau, W.W.; Witte, H.; et al.(2008). The Effect of Magnetic Field on the Position of HTS Leads and the Cooler in the Services Tower of the MICE Focusing Magnet. Lawrence Berkeley National Laboratory. Lawrence Berkeley National Laboratory: Lawrence Berkeley National Laboratory. Retrieved from: http://www.escholarship.org/uc/item/5xq9s9hs
Publication Year :
2008
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 2008.

Abstract

The MICE focusing solenoids have three 4 K coolers (two for the superconducting magnet and one for the liquid absorber) and four HTS leads that feed the current to the focusing coils. The focusing solenoids produce large radial external fields when they operate with the polarity of the two coils in opposition (the gradient or flip mode). When the MICE focusing coils operate at the same polarity (the solenoid or non-flip mode), the fields are much smaller and parallel to the axis of the solenoid. The worst-case magnetic field affects the selection of the cooler and the HTS leads. This magnetic field can also determine the height of the service towers that house the three coolers and the four HTS leads. This paper shows the criteria used for Cooler selection, HTS lead selection, and the position of both the cooler and leads with respect to the solenoid axis of rotation. © 2008 IEEE.

Details

ISSN :
15582515 and 10518223
Volume :
18
Database :
OpenAIRE
Journal :
IEEE Transactions on Applied Superconductivity
Accession number :
edsair.doi.dedup.....7270f4a8133a44970b56c21777f72f28
Full Text :
https://doi.org/10.1109/tasc.2008.921273