Back to Search Start Over

Aerogel-Based Ring-Imaging Cherenkov counter in the Belle II experiment

Authors :
S. Nishida
Iki Adachi
S. Kakimimoto
M. Yoshizawa
Y. Yusa
Kohei Ogawa
Tomoyuki Konno
K. Noguchi
K. Hataya
Makoto Tabata
H. Kindo
F. Le Diberder
T. Sumiyoshi
H. Kawai
M. Machida
L. Santelj
S. Ogawa
S. Korpar
M. Nishimura
M. Mrvar
T. Kumita
Hidekazu Kakuno
P. Krizan
M. Yonenaga
L. Burmistrov
S. Tamechika
Takeo Kawasaki
R. Pestotnik
Y. Lai
Laboratoire de l'Accélérateur Linéaire (LAL)
Université Paris-Sud - Paris 11 (UP11)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)
Source :
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference, 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference, Nov 2018, Sydney, Australia. ⟨10.1109/NSSMIC.2018.8824726⟩
Publication Year :
2018
Publisher :
HAL CCSD, 2018.

Abstract

International audience; In the charged particle identification system of the Belle II experiment, an aerogel-based proximity focusing ring-imaging Cherenkov (ARICH) counter is installed in the forward end-cap region of the Belle II detector. The goal is to enhance the power of separation between kaons and pions up to and above 4σ for momenta up to 4 GeV/c, which is critical to the study of CP violation involved in B decays. The counter is made of aerogel tiles with refractive indices n of 1.045 and 1.055, transmission lengths of 30-40 mm, and dimensions of 18 × 18 × 2 cm3. A 144-channel HAPD (Hybrid Avalanche Photo Detector) is adopted as a photo-detector, and the HAPD signal processing is performed using ASICs (Application Specific Integrated Circuit) to digitize the signal and FPGAs (Field Programmable Gate Array) for data processing.During Phase II operation of SuperKEKB, the commissioning of ARICH is done both with cosmic rays and beam collisions. The Cherenkov rings are clearly observed, and the performance of the hardware system and identification algorithm is being evaluated. In this paper, we will report on the construction of ARICH and on the initial performance of the detector obtained during the commissioning.

Details

Language :
English
Database :
OpenAIRE
Journal :
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference, 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference, Nov 2018, Sydney, Australia. ⟨10.1109/NSSMIC.2018.8824726⟩
Accession number :
edsair.doi.dedup.....715cb05b769dd1578dfe6280e699147c
Full Text :
https://doi.org/10.1109/NSSMIC.2018.8824726⟩