Back to Search
Start Over
Improved detection of molecularly targeted iron oxide particles in mouse brain using B0 field stabilised high resolution MRI
- Source :
- Magnetic Resonance Imaging
- Publication Year :
- 2020
- Publisher :
- Elsevier, 2020.
-
Abstract
- Purpose: High resolution multi-gradient echo (MGE) scanning is typically used for detection of molecularly targeted iron oxide particles. The images of individual echoes are often combined to generate a composite image with improved SNR from the early echoes and boosted contrast from later echoes. In 3D implementations prolonged scanning at high gradient duty cycles induces a B0 shift that predominantly affects image alignment in the slow phase encoding dimension of 3D MGE images. The effect corrupts the composite echo image and limits the image resolution that is realised. A real-time adaptive B0 stabilisation during respiration gated 3D MGE scanning is shown to reduce image misalignment and improve detection of molecularly targeted iron oxide particles in composite images of the mouse brain. Methods: An optional B0 measurement block consisting of a 16 μs hard pulse with FA 1°, an acquisition delay of 3.2 ms, followed by gradient spoiling in all three axes was added to a respiration gated 3D MGE scan. During the acquisition delay of each B0 measurement block the NMR signal was routed to a custom built B0 stabilisation unit which mixed the signal to an audio frequency nominally centred around 1000 Hz to enable an Arduino based single channel receiver to measure frequency shifts. The frequency shift was used to effect correction to the main magnetic field via the B0 coil. The efficacy of B0 stabilisation and respiration gating was validated in vivo and used to improve detection of molecularly targeted microparticles of iron oxide (MPIO) in a mouse model of acute neuroinflammation. Results: Without B0 stabilisation 3D MGE image data exhibit varying mixtures of translation, scaling and blurring, which compromise the fidelity of the composite image. The real-time adaptive B0 stabilisation minimises corruption of the composite image as the images from the different echoes are properly aligned. The improved detection of molecularly targeted MPIO easily compensates for the scan time penalty of 14% incurred by the B0 stabilisation method employed. Respiration gating of the B0 measurement and the MRI scan was required to preserve high resolution detail, especially towards the back of the brain. Conclusions: High resolution imaging for the detection of molecularly targeted iron oxide particles in the mouse brain requires good stabilisation of the main B0 field, and can benefit from a respiration gated image acquisition strategy.
- Subjects :
- Materials science
Channel (digital image)
Biomedical Engineering
Biophysics
Phase (waves)
Molecular imaging
Composite image filter
Signal
Ferric Compounds
Article
Iron oxide particles
030218 nuclear medicine & medical imaging
03 medical and health sciences
Mice
0302 clinical medicine
Imaging, Three-Dimensional
Image Processing, Computer-Assisted
Animals
Radiology, Nuclear Medicine and imaging
High resolution
Image resolution
Audio frequency
Inflammation
Mice, Inbred BALB C
Pulse (signal processing)
Brain
B0 correction
Magnetic Resonance Imaging
Magnetic Fields
Female
030217 neurology & neurosurgery
Biomedical engineering
B0 lock
Subjects
Details
- Language :
- English
- ISSN :
- 18735894 and 0730725X
- Volume :
- 67
- Database :
- OpenAIRE
- Journal :
- Magnetic Resonance Imaging
- Accession number :
- edsair.doi.dedup.....707ef4299141ff66e69393ec2f2ef0c0