Shielded-coaxial-cable coils as receive and transceive array elements for 7T human MRI
- Source :
- Magnetic Resonance in Medicine, 83(3), 1135-1146. WILEY, Magnetic Resonance in Medicine
- Publication Year :
- 2020
- Publisher :
- WILEY, 2020.
-
Abstract
- PURPOSE: To investigate the use of shielded-coaxial-cable (SCC) coils as elements for multi-channel receive-only and transceive arrays for 7T human MRI and to compare their performance with equivalently sized conventional loop coils. METHODS: The SCC coil element consists of a coaxial loop with interrupted central conductor at the feed-point side and an interrupted shield at the opposite point. Inter-element decoupling, transmit efficiency, and sample heating were compared with results from conventional capacitively segmented loop coils. Three multichannel arrays (a 4-channel receive-only array and 8- and 5-channel transceive arrays) were constructed. Their inter-element decoupling was characterized via measured noise correlation matrices and additionally under different flexing conditions of the coils. Thermal measurements were performed and in vivo images were acquired. RESULTS: The measured and simulated B 1 + maps of both SCC and conventional loops were very similar. For all the arrays constructed, the inter-element decoupling was much greater for the SCC elements than the conventional ones. Even under high degrees of flexion, the coupling coefficients were lower than -10 dB, with a much smaller frequency shift than for the conventional coils. CONCLUSION: Arrays constructed from SCC elements are mechanically flexible and much less sensitive to changes of the coil shape from circular to elongated than arrays constructed from conventional loop coils, which makes them suitable for construction of size adjustable arrays.
- Subjects :
- coaxial coils
Materials science
Coaxial cable
Acoustics
7T arrays
Thermometry
Signal-To-Noise Ratio
Electromagnetic radiation
030218 nuclear medicine & medical imaging
law.invention
03 medical and health sciences
0302 clinical medicine
law
Shield
Shielded cable
Image Processing, Computer-Assisted
Humans
Radiology, Nuclear Medicine and imaging
Computer Simulation
Knee
transceive coils
Full Paper
Phantoms, Imaging
Electromagnetic Radiation
Reproducibility of Results
Equipment Design
Magnetic Resonance Imaging
Conductor
Electromagnetic coil
Full Papers—Hardware and Instrumentation
Coaxial
030217 neurology & neurosurgery
Decoupling (electronics)
Algorithms
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Magnetic Resonance in Medicine, 83(3), 1135-1146. WILEY, Magnetic Resonance in Medicine
- Accession number :