Back to Search Start Over

Calibration of nuclear recoils at the 100 eV scale using neutron capture

Authors :
R. Cerulli
Leo Stodolsky
Olivier Litaize
A. Letourneau
M. Vivier
A. Chalil
F. Cappella
A. Langenkämper
F. Gunsing
E. Mazzucato
Olivier Serot
A. Erhart
D.V. Poda
Eric Dumonteil
A. Giuliani
L. Pattavina
N. Schermer
L. Thulliez
T. Ortmann
R. D. Strauss
N. Casali
Thierry Lasserre
D. Lhuillier
M. Kaznacheeva
P. de Marcillac
G. Soum
M. Vignati
V. Wagner
A. Chebboubi
C. Nones
T. Materna
A. Wex
E. Jericha
R. Rogly
B. Mauri
S. Marnieros
A. Kinast
Institut de Recherches sur les lois Fondamentales de l'Univers (IRFU)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay
CEA Cadarache
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)
Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab)
Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS)
Source :
Journal of Instrumentation, Journal of Instrumentation, IOP Publishing, 2021, 16 (07), pp.P07032. ⟨10.1088/1748-0221/16/07/P07032⟩, JINST, JINST, 2021, 16 (07), pp.P07032. ⟨10.1088/1748-0221/16/07/P07032⟩
Publication Year :
2020
Publisher :
arXiv, 2020.

Abstract

The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $\gamma$ emission following thermal neutron capture. In particular, several MeV-scale single-$\gamma$ transitions induce well-defined nuclear recoil peaks in the 100 eV range. Using the FIFRELIN code, complete schemes of $\gamma$-cascades for various isotopes can be predicted with high accuracy to determine the continuous background of nuclear recoils below the calibration peaks. We present a comprehensive experimental concept for the calibration of CaWO$_4$ and Ge cryogenic detectors at a research reactor. For CaWO$_4$ the simulations show that two nuclear recoil peaks at 112.5 eV and 160.3 eV should be visible above background simply in the spectrum of the cryogenic detector. Then we discuss how the additional tagging for the associated $\gamma$ increases the sensitivity of the method and extends its application to a wider energy range and to Ge cryogenic detectors.<br />Comment: 21 pages, 8 figures

Details

ISSN :
17480221
Database :
OpenAIRE
Journal :
Journal of Instrumentation, Journal of Instrumentation, IOP Publishing, 2021, 16 (07), pp.P07032. ⟨10.1088/1748-0221/16/07/P07032⟩, JINST, JINST, 2021, 16 (07), pp.P07032. ⟨10.1088/1748-0221/16/07/P07032⟩
Accession number :
edsair.doi.dedup.....6f621e3e9b404e571b6781f4288b3b1d
Full Text :
https://doi.org/10.48550/arxiv.2011.13803