An Improved Harmonic Suppression Control Strategy for the Hybrid Microgrid Bidirectional AC/DC Converter
- Source :
- IEEE Access, Vol 8, Pp 220422-220436 (2020)
- Publication Year :
- 2020
- Publisher :
- IEEE, 2020.
-
Abstract
- The nonlinear load in AC/DC hybrid microgrid seriously affects the power transmission quality of bidirectional AC/DC interlinking converter (BIC). In this article, an improved Fryze-Buchholz-Depenbrock (FBD) harmonic current detection method combined with droop control is designed to suppress harmonic current control strategy. The decoupled double synchronous reference frame phase locked loop (DDSRF-PLL) with self decoupled network is used to eliminate the negative sequence fundamental frequency component, and the accurate phase detection can also be realized when affected by nonlinear load. The least mean square (LMS) algorithm adaptive filter can enhance the dynamic response ability when the load current suddenly changes. To solve the problem that the cut-off frequency of low pass filter (LPF) can not take into account the detection accuracy and response speed of FBD harmonic current detection method. Finally, Matlab/Simulink is used for simulation verification. The simulation results show that the improved control strategy not only realizes the bidirectional flow of power and maintains the DC bus voltage stability, but also reduces the total harmonic distortion (THD) at point of common coupling (PCC) by 0.45% compared with the traditional FBD control strategy. And the effectiveness and feasibility of the design method are proved.
- Subjects :
- General Computer Science
Computer science
Low-pass filter
harmonic current suppression
0211 other engineering and technologies
02 engineering and technology
nonlinear load
improved FBD
Phase detector
Harmonic analysis
Control theory
0202 electrical engineering, electronic engineering, information engineering
General Materials Science
Voltage droop
droop control strategy
Total harmonic distortion
Power transmission
021103 operations research
020208 electrical & electronic engineering
General Engineering
Fundamental frequency
AC/DC hybrid microgrid
Adaptive filter
Phase-locked loop
bidirectional AC/DC interlinking converter
Harmonic
Microgrid
lcsh:Electrical engineering. Electronics. Nuclear engineering
lcsh:TK1-9971
Subjects
Details
- Language :
- English
- ISSN :
- 21693536
- Volume :
- 8
- Database :
- OpenAIRE
- Journal :
- IEEE Access
- Accession number :
- edsair.doi.dedup.....6eb6d188913026c1fe2255caa3410b02