Back to Search Start Over

Feasibility of using the TOSCA telescreening procedures for diabetic retinopathy

Authors :
Gudrun Wirkner Zahlmann
Toke Bek
L. Mazik
B. Liesenfeld
Siegfried Dipl Phys Schneider
Hans Schuell
S. Hatcher
M. Morgan
E. M. Kohner
D. R. Owens
Stephen D. Luzio
Source :
Luzio, S, Hatcher, S, Zahlmann, G, Mazik, L, Morgan, M, Liesenfeld, B, Bek, T, Schuell, H, Schneider, S, Owens, D R & Kohner, E 2004, ' Feasibility of using the TOSCA telescreening procedures for diabetic retinopathy ', Diabet. Med., vol. 21, no. 10, pp. 1121-1128 ., Aarhus University
Publication Year :
2004
Publisher :
Wiley, 2004.

Abstract

Aims The TOSCA project was set up to establish a tele-ophthalmology service to screen for diabetic retinopathy (DR) in Europe. The aim of this study was to determine the feasibility of establishing telemedicine-based digital screening for detecting DR and to evaluate the satisfaction of both patients and healthcare professionals with the screening procedures used within the TOSCA project. Methods The study was a non-randomized, multicentre study carried out in four different countries over a period of 3 months. Patients (n = 390) with diabetes aged > 12 years were included. Two digital retinal images per eye (macular and nasal) were taken and exported to a central server. Patients were asked to complete a questionnaire to assess satisfaction. Accredited graders carried out grading remotely and the results were reported back to the referring centre. Previously graded patient data chosen randomly to represent examples of both DR and no DR were also sent anonymously to the grading centre at a frequency of approximately every 10 patients. Results Most (99%) of the images were assessable enabling a retinopathy grade to be assigned to the patient. Patients found the retinal photography procedures acceptable; only 6% in one centre would not recommend the procedure. Healthcare professionals (photographers and graders) were also satisfied with the overall procedures. The average time taken to grade each patient was approximately 5 min. Conclusions This study demonstrated that it is feasible to electronically transmit and grade retinal images remotely using the TOSCA process. Built-in quality assurance procedures proved acceptable.

Details

ISSN :
14645491 and 07423071
Volume :
21
Database :
OpenAIRE
Journal :
Diabetic Medicine
Accession number :
edsair.doi.dedup.....6be5aada18cc09eefd015178c1b52a66
Full Text :
https://doi.org/10.1111/j.1464-5491.2004.01305.x