A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses
- Source :
- BioMedical Engineering, BioMedical Engineering OnLine, Vol 16, Iss 1, Pp 1-20 (2017)
- Publication Year :
- 2017
-
Abstract
- Background Load cells are often used in rehabilitation robotics to monitor human–robot interaction. While load cells are accurate and suitable for the stationary end-point robots used in rehabilitation hospitals, their cost and inability to conform to the shape of the body hinder their application in developing affordable and wearable robotic orthoses for assisting individuals in the activities of daily living. This exploratory work investigates the possibility of using an alternative technology, namely compliant polymeric air cushions, to measure interaction forces between the user and a wearable rigid structure. Methods A polymeric air cushion was designed, analyzed using a finite element model (FEM), and tested using a bench-top characterization system. The cushions underwent repeatability testing, and signal delay testing from a step response while increasing the length of the cushion’s tubes. Subsequently, a 3D printed wrist brace prototype was integrated with six polymeric air cushions and tested in static conditions where a volunteer exerted isometric pronation/supination torque and forces in vertical and horizontal directions. The load measured by integrating data recorded by the six sensors was compared with force data measured by a high quality load cell and torque sensor. Results The FEM and experimental data comparison was within the error bounds of the external differential pressure sensor used to monitor the pressure inside the cushion. The ratio obtained experimentally between the pressure inside the pressure cushion and the 8 N applied load deviated by only 1.28% from the FEM. A drift smaller than 1% was observed over 10 cycles. The rise times of the cushion under an 8 N step response for a 0.46, 1.03, and 2.02 m length tube was 0.45, 0.39, and 0.37 s. Tests with the wrist brace showed a moderate root mean square error (RMSE) between the force estimated by the pressure cushions and the external load cells. Specifically, the RMSE was 13 mNm, 500 mN, and 1.24 N for forearm pronation/supination torque, vertical force, and horizontal force, respectively. Conclusions The use of compliant pressure cushions was shown to be promising for monitoring interaction forces between the forearm and a rigid brace. This work lays the foundation for the future design of an array of pressure cushions for robotic orthoses. Future research should also investigate the compatibility of these polymeric cushions for data acquisition during functional magnetic resonance imaging in shielded rooms.
- Subjects :
- 030506 rehabilitation
Engineering
Wrist brace
Mechanical engineering
Pilot Projects
TS
0302 clinical medicine
Nuclear Medicine and Imaging
Transducers, Pressure
Polymer
Radiological and Ultrasound Technology
Air
Rehabilitation
General Medicine
Structural engineering
Equipment Design
Robotics
Exoskeleton Device
Exoskeleton
Forearm
lcsh:R855-855.5
Computer-Aided Design
Force
Polydimethylsiloxane (PDMS)
Sensors
Wearable
Equipment Failure Analysis
Humans
Manometry
Pressure
Reproducibility of Results
Sensitivity and Specificity
Man-Machine Systems
Orthotic Devices
Biomaterials
Biomedical Engineering
Radiology, Nuclear Medicine and Imaging
0305 other medical science
Radiology
lcsh:Medical technology
Transducers
Load cell
03 medical and health sciences
TA164
Torque sensor
Radiology, Nuclear Medicine and imaging
Rehabilitation robotics
business.industry
Research
Pressure sensor
Orthotic device
Brace
TA174
Cushion
business
030217 neurology & neurosurgery
Subjects
Details
- Language :
- English
- ISSN :
- 1475925X
- Database :
- OpenAIRE
- Journal :
- BioMedical Engineering, BioMedical Engineering OnLine, Vol 16, Iss 1, Pp 1-20 (2017)
- Accession number :
- edsair.doi.dedup.....6be3028d327d4f66d0630c9709eb4f3d