Back to Search Start Over

Mapping the Amplitude and Position Response of Double Sided Silicon Strip Detectors with Monocromatic Single Protons

Authors :
F. Amorini
S. Gianì
F. Porto
F. Rizzo
T. Parsani
S. Santoro
Giuseppe Verde
Ismael Martel
Lucrezia Auditore
S. Pirrone
E. V. Pagano
Triestino Minniti
G. Cardella
Ivano Lombardo
A. Chbihi
D. Loria
E. Geraci
A. M. Sánchez-Benítez
A. Pagano
M. Trimachi
F. Riccio
P. Zambon
Chiara Guazzoni
F. Taccetti
Antonio Trifiro
G. Lanzalone
C. Maiolino
G. V. Montemurro
L. Francalanza
S. Lo Nigro
J. A. Dueñas
C. Boiano
R. Berjillos
E. La Guidara
Mariano Vigilante
M. Papa
L. Carraresi
Andrea Castoldi
L. Acosta
E. De Filippo
P. Russotto
A. Anzalone
G. Politi
Grand Accélérateur National d'Ions Lourds (GANIL)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)
Acosta, L.
Amorini, F.
Anzalone, A.
Auditore, L.
Boiano, C.
Cardella, G.
Carraresi, L.
Castoldi, A.
Chbihi, A.
De Filippo, E.
Francalanza, L.
Geraci, E.
Giani, S.
Guazzoni, C.
La Guidara, E.
Lanzalone, G.
Lombardo, I.
Lo Nigro, S.
Loria, D.
Maiolino, C.
Martel, I.
Minniti, T.
Montemurro, G.
Pagano, A.
Pagano, E.
Papa, M.
Parsani, T.
Pirrone, S.
Politi, G.
Porto, F.
Riccio, F.
Rizzo, F.
Russotto, P.
Sánchez-Benítez, A.
Duenas, J.
Berjillos, R.
Santoro, S.
Taccetti, F.
Trifiro, A.
Trimachi, M.
Verde, G.
Vigilante, M.
Zambon, P.
Source :
ResearcherID, Nuclear Science Symposium and Medical Imaging Conference, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), Oct 2012, Anaheim, United States. pp.1358-1364, ⟨10.1109/NSSMIC.2012.6551331⟩
Publication Year :
2012
Publisher :
IEEE / Institute of Electrical and Electronics Engineers Incorporated:445 Hoes Lane:Piscataway, NJ 08854:(800)701-4333, (732)981-0060, EMAIL: subscription-service@ieee.org, INTERNET: http://www.ieee.org, Fax: (732)981-9667, 2012.

Abstract

International audience; We are currently developing a novel detection system featuring high angular and energy resolution and able to reconstruct the particles momentum at high precision for different physical cases in multi-fragmentation nuclear physics experiments, based on Double Sided Silicon Strip Detectors as ΔE stages aimed at performing also pulse shape analysis for fragments stopping therein. We carried out a detailed qualification of the performance of the strip detectors. In order to provide the detector response matrix we used a pulsed monoenergetic proton beam. The paper reviews the pulsed proton beam facility of the LaBeC of INFN - Sezione di Firenze and present the results of the characterization of the DSSSD prototypes with the pulsed proton beam. In particular we will discuss the amplitude and time response mapping and we will present the analysis of the dependence of the signal shape as a function of the position of interaction.

Details

Language :
English
Database :
OpenAIRE
Journal :
ResearcherID, Nuclear Science Symposium and Medical Imaging Conference, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), Oct 2012, Anaheim, United States. pp.1358-1364, ⟨10.1109/NSSMIC.2012.6551331⟩
Accession number :
edsair.doi.dedup.....6b9e2845c713e257564f4ba7b88e5b0a