Back to Search Start Over

Blood loss and transfusion risk in robotic-assisted knee arthroplasty: A retrospective analysis

Authors :
Kieran Dhillon
Woo Jae Kim
Ravi Popat
Omar Zakieh
Piyush Mahapatra
Hasaan Khan
Dinesh Nathwani
Source :
The international journal of medical robotics + computer assisted surgery : MRCASREFERENCES. 17(6)
Publication Year :
2021

Abstract

BACKGROUND The purpose of this study was to compare total blood loss and the risk of receiving a blood transfusion in robotic-assisted total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) against conventional jig-based techniques. METHODS Robotic TKA (n = 50) and UKA (n = 50) patients were matched to contemporary controls for TKA (n = 50) and UKA (n = 50) and retrospectively analysed. RESULTS Robotic TKA patients experienced 23.7% less blood loss compared to conventional TKA patients (911.0 ml vs 1193.7 ml, p