Back to Search
Start Over
Effectiveness of Multiple Internal Standards: Deuterated Analogues of Methylenedioxymethamphetamine, Methylenedioxyamphetamine, Methamphetamine, and Amphetamine
- Source :
- Journal of Analytical Toxicology. 28:650-654
- Publication Year :
- 2004
- Publisher :
- Oxford University Press (OUP), 2004.
-
Abstract
- With the increasing abuse of methylenedioxymethamphetamine (MDMA) thereby requiring analysis, we have undertaken a systematic evaluation on parameters associated with the analysis of MDMA and related compounds, including methylenedioxyamphetamine (MDA), methamphetamine (MA), and amphetamine (AM). Parameters studied included three solid-phase adsorbents, five derivatization reagents, and four deuterated internal standards (IS). This report examines whether differences in quantitation data derived from the use of four ISs (one for each analyte) and two ISs (one for AM and MA, one for MDA and MDMA) are statistically significant. Two types of samples were included in this study. The first type (Type I) included four replicate sets of standard solutions prepared in urine matrix. All analytes (AM, MA, MDA, and MDMA) were included in all samples, and these analytes' concentrations in each set were at five levels (100, 250, 500, 1000, and 2000 ng/mL). Four deuterated analogues (MA-d(8), AM-d(8), MDMA-d(5), and MDA-d(5)) at 500 ng/mL were also included in all solutions. The second type of samples (Type II) included 25 case urine specimens. Most of these specimens contained MA/AM and/or MDMA/MDA. The specific objective of this study is to determine whether the 4-IS approach can indeed generate better quantitative data than a less-costly 2-IS. For Type I samples, where the true concentrations of the analytes are known, two-sample t-test is adapted to examine whether the two sets of prediction errors (i.e., known concentration minus calculated concentration) resulting from the 4-IS and the 2-IS approaches are statistically different. For Type II samples, where the analytes' true concentrations are unknown, one-sample t-test was adapted to determine whether the difference of the quantitation results derived from the 4-IS and the 2-IS approaches is statistically significant. Statistical analysis of quantitation data derived from Types I and II samples indicates that differences in MDA and MDMA concentrations resulting from the use of one (MDA-d(5) or MDMA-d(5)) or two (MDA-d(5) and MDMA-d(5)) are statistically nonsignificant. On the other hand, similar analysis on data derived from Type I samples indicate the use of the analytes' respective deuterated analogues as the ISs appear to generate better quantitative data for AM and MA.
- Subjects :
- Chemical Health and Safety
Chemistry
N-Methyl-3,4-methylenedioxyamphetamine
Health, Toxicology and Mutagenesis
Reproducibility of Results
MDMA
Reference Standards
Methamphetamine
Pharmacology
Deuterium
Toxicology
Metanfetamina
Metamfetamine
Analytical Chemistry
Substance Abuse Detection
chemistry.chemical_compound
medicine
Humans
Environmental Chemistry
Amphetamine
Derivatization
Amfetamine
3,4-Methylenedioxyamphetamine
medicine.drug
Subjects
Details
- ISSN :
- 19452403 and 01464760
- Volume :
- 28
- Database :
- OpenAIRE
- Journal :
- Journal of Analytical Toxicology
- Accession number :
- edsair.doi.dedup.....6a065bac6a59dd51faf089d3769bc17a
- Full Text :
- https://doi.org/10.1093/jat/28.8.650