Back to Search
Start Over
An Automated Filter Paper Dithionite Test for the Detection of Hemoglobin S
- Source :
- American Journal of Clinical Pathology. 60:319-322
- Publication Year :
- 1973
- Publisher :
- Oxford University Press (OUP), 1973.
-
Abstract
- The automated dithionite test for the detection of hemoglobin S has been modified for use with AutoAnalyzers having a filter paper read-out. This method was compared with results of hemoglobin electrophoresis in 425 individuals, of whom 58 were positive for hemoglobin S. The two methods were in complete agreement. The automated filter paper dithionite test is a rapid, economical, accurate method for detection of hemoglobin S and could be easily incorporated into currently available mass screening equipment.
- Subjects :
- Paper
Hemoglobin s
Autoanalysis
Chromatography
Hemoglobin electrophoresis
Filter paper
Hemoglobins, Abnormal
Hemoglobin, Sickle
General Medicine
Acetates
Buffers
Blood Protein Electrophoresis
Dithionite
chemistry.chemical_compound
chemistry
Methods
Humans
Sulfites
Hemoglobin
Cellulose
Filtration
Mass screening
Subjects
Details
- ISSN :
- 19437722 and 00029173
- Volume :
- 60
- Database :
- OpenAIRE
- Journal :
- American Journal of Clinical Pathology
- Accession number :
- edsair.doi.dedup.....69eeba8a49351229ca653ff671039356