Back to Search Start Over

Pharmacist-physician collaborative care for outpatients with left ventricular assist devices using a cloud-based home medical management information-sharing system: a case report

Authors :
Shinichi Nomoto
Asami Sukeishi
Hideo Kanemitsu
Kazuo Matsubara
Yoshiki Katada
Yuki Sato
Kenji Minakata
Momoe Utsumi
Atsushi Yonezawa
Takayuki Nakagawa
Shunsaku Nakagawa
Satoshi Imai
Noriaki Kitada
Katsuyuki Matsumura
Kenji Minatoya
Source :
Journal of Pharmaceutical Health Care and Sciences, Vol 7, Iss 1, Pp 1-5 (2021), Journal of Pharmaceutical Health Care and Sciences
Publication Year :
2021
Publisher :
Springer Science and Business Media LLC, 2021.

Abstract

Background The standard anticoagulation therapy for patients implanted with left ventricular assist devices (LVADs) includes warfarin therapy. We developed a cloud-based home medical management information-sharing system named as LVAD@home. The LVAD@home system is an application designed to be used on iPad tablet computers. This system enables the sharing of daily information between a patient and care providers in real time. In this study, we reported cases of outpatients with LVADs using this system to manage anticoagulation therapy. Case presentation The patient, a man in his 40s with end-stage heart failure owing to non-ischemic dilated cardiomyopathy, underwent LVAD implantation and warfarin was started on postoperative day 1. He started to use LVAD@home to manage warfarin therapy after discharge (postoperative day 47). He sent his data to care providers daily. By using this system, the pharmacist observed his signs of reduced dietary intake 179 days after discharge, and after consulting the physician, told the patient to change the timing of the next measurement earlier than usual. On the next day, the prothrombin time-international normalized ratio increased from 2.0 to 3.0, and thus the dose was decreased by 0.5 mg. Four patients used this system to monitor warfarin therapy from October 2015 to March 2018. In these patients, the time in therapeutic range was 90.1 ± 1.3, which was higher than that observed in previous studies. Additionally, there were no thromboembolic events or bleeding events. Conclusions The cloud-based home management system can be applied to share real-time patient information of factors, including dietary intake that interact with warfarin. It can help to improve long-term anticoagulation outcomes in patients implanted with LVAD.

Details

ISSN :
20550294
Volume :
7
Database :
OpenAIRE
Journal :
Journal of Pharmaceutical Health Care and Sciences
Accession number :
edsair.doi.dedup.....6927c714ebb6f5dcbd3cbf5f281953cd