Back to Search
Start Over
Temperature‐corrected proton density fat fraction estimation using chemical shift‐encoded MRI in phantoms
- Source :
- Magnetic Resonance in Medicine. 86:69-81
- Publication Year :
- 2021
- Publisher :
- Wiley, 2021.
-
Abstract
- Purpose Chemical shift-encoded MRI (CSE-MRI) is well-established to quantify proton density fat fraction (PDFF) as a quantitative biomarker of hepatic steatosis. However, temperature is known to bias PDFF estimation in phantom studies. In this study, strategies were developed and evaluated to correct for the effects of temperature on PDFF estimation through simulations, temperature-controlled experiments, and a multi-center, multi-vendor phantom study. Theory and methods A technical solution that assumes and automatically estimates a uniform, global temperature throughout the phantom is proposed. Computer simulations modeled the effect of temperature on PDFF estimation using magnitude-, complex-, and hybrid-based CSE-MRI methods. Phantom experiments were performed to assess the temperature correction on PDFF estimation at controlled phantom temperatures. To assess the temperature correction method on a larger scale, the proposed method was applied to data acquired as part of a nine-site multi-vendor phantom study and compared to temperature-corrected PDFF estimation using an a priori guess for ambient room temperature. Results Simulations and temperature-controlled experiments show that as temperature deviates further from the assumed temperature, PDFF bias increases. Using the proposed correction method and a reasonable a priori guess for ambient temperature, PDFF bias and variability were reduced using magnitude-based CSE-MRI, across MRI systems, field strengths, protocols, and varying phantom temperature. Complex and hybrid methods showed little PDFF bias and variability both before and after correction. Conclusion Correction for temperature reduces temperature-related PDFF bias and variability in phantoms across MRI vendors, sites, field strengths, and protocols for magnitude-based CSE-MRI, even without a priori information about the temperature.
- Subjects :
- Correction method
Materials science
Temperature
Reproducibility of Results
Proton density fat fraction
Fat quantification
Magnetic Resonance Imaging
Imaging phantom
030218 nuclear medicine & medical imaging
Computational physics
03 medical and health sciences
0302 clinical medicine
Liver
Radiology, Nuclear Medicine and imaging
Temperature correction
Protons
Phantom studies
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 15222594 and 07403194
- Volume :
- 86
- Database :
- OpenAIRE
- Journal :
- Magnetic Resonance in Medicine
- Accession number :