Back to Search
Start Over
Repeat Ablation for Atrial Fibrillation Recurrence Post Cryoballoon or Radiofrequency Ablation in the FIRE AND ICE Trial
- Source :
- Circulation: Arrhythmia and Electrophysiology. 12
- Publication Year :
- 2019
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2019.
-
Abstract
- Background: The FIRE AND ICE trial assessed efficacy and safety of pulmonary vein (PV) isolation using cryoballoon versus radiofrequency current (RFC) ablation in patients with drug refractory, symptomatic, paroxysmal atrial fibrillation (AF). The purpose of the current study was to assess index lesion durability as well as reablation strategy and outcomes in trial patients undergoing a reablation procedure. Methods: Patients with reablation procedures during FIRE AND ICE were retrospectively consented and enrolled at 13 trial centers. The first reablation for each patient was included in the analysis. Documented arrhythmias before reablation, number and location of reconnected PVs, lesions created during reablations, procedural characteristics, and acute as well as long-term outcomes were assessed. Results: Eighty-nine (36 cryoballoon and 53 RFC) patients were included in this study. Paroxysmal atrial fibrillation was the predominant recurrent arrhythmia (69%) before reablation. Reablations occurred at a median of 173 and 182 days ( P =0.54) in the cryoballoon and RFC cohorts, respectively. The number of reconnected PVs was significantly higher in the RFC than the cryoballoon group (2.1±1.4 versus 1.4±1.1; P =0.010), which was driven by significantly more reconnected left superior PVs and markedly more reconnected right superior PVs. The number of (predominantly RFC) lesions applied during reablation was significantly greater in patients originally treated with RFC (3.3±1.3 versus 2.5±1.5; P =0.015) with no difference in overall acute success ( P =0.70). After reablation, no differences in procedure-related rehospitalization or antiarrhythmic drug utilization were observed between cohorts. Conclusions: At reablation, patients originally treated with the cryoballoon had significantly fewer reconnected PVs, which may reflect RFC catheter instability in certain left atrial regions, and thus required fewer lesions for reablation success. Repeat ablations were predominantly performed with RFC and resulted in similar acute success, duration of hospitalization, and antiarrhythmic drug prescription between the study cohorts. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03314753.
- Subjects :
- Adult
Male
Reoperation
medicine.medical_specialty
Time Factors
Adolescent
Radiofrequency ablation
medicine.medical_treatment
Catheter Ablation/adverse effects
Action Potentials
Catheter ablation
Cryosurgery
law.invention
Pulmonary vein
Young Adult
Randomized controlled trial
Refractory
Heart Rate
Recurrence
law
Physiology (medical)
Atrial Fibrillation
Atrial Fibrillation/diagnosis
medicine
Humans
In patient
Aged
Randomized Controlled Trials as Topic
Retrospective Studies
Cryosurgery/adverse effects
business.industry
Pulmonary Veins/physiopathology
Atrial fibrillation
Middle Aged
medicine.disease
Ablation
Europe
Treatment Outcome
Pulmonary Veins
Catheter Ablation
Female
Radiology
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 19413084 and 19413149
- Volume :
- 12
- Database :
- OpenAIRE
- Journal :
- Circulation: Arrhythmia and Electrophysiology
- Accession number :
- edsair.doi.dedup.....647af0981bcf3fa57300a78cb4bf0db5
- Full Text :
- https://doi.org/10.1161/circep.119.007247