Back to Search
Start Over
Measuring Heart Rate Variability Using Commercially Available Devices in Healthy Children: A Validity and Reliability Study
- Source :
- European Journal of Investigation in Health, Psychology and Education, Volume 10, Issue 1, Pages 29-404
- Publication Year :
- 2020
- Publisher :
- MDPI AG, 2020.
-
Abstract
- Heart rate variability (HRV) is an accepted method for determining autonomic nervous system activity and cardiovascular risk in various populations. This study assessed the validity and reliability of a commercially available finger photoplethysmography (PPG) system for measuring pediatric HRV in a real-world setting. Sixteen healthy children (4.06 ± 0.58 years) were recruited. The PPG system was compared to the Polar H10 heart rate (HR) sensor validated against ECG (gold standard) for HRV measurement. Seated short-term resting R-R intervals were recorded simultaneously using both systems. Recordings were performed on 3 days at the participants’ school. Paired t-tests, effect sizes and Bland–Altman analyses determined the validity of the PPG system. The relative and absolute reliability of both systems were calculated. No HRV parameters were valid for the PPG system. Polar H10 yielded moderate (0.50–0.75) to good (0.75–0.90) relative reliability with R-R intervals and the standard deviation of instantaneous and continuous R-R variability ratio showing the best results (ICCs = 0.84). Polar H10 displayed better absolute reliability with the root mean square of successive differences, R-R intervals and HR showing the lowest values (TEM% &lt<br />12%). The use of the Polar H10 and not the PPG system is encouraged for HRV measurement of young children in an educational real-world setting.
- Subjects :
- validity
medicine.medical_specialty
Relative reliability
photoplethysmography or PPG
Validity
Polar H10
030204 cardiovascular system & hematology
Article
Standard deviation
03 medical and health sciences
0302 clinical medicine
children
Photoplethysmogram
Internal medicine
Heart rate
Developmental and Educational Psychology
Medicine
Heart rate variability
Applied Psychology
Reliability (statistics)
reliability
autonomic nervous system or ANS
business.industry
Gold standard (test)
heart rate variability or HRV
Clinical Psychology
Cardiology
business
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 22549625
- Volume :
- 10
- Database :
- OpenAIRE
- Journal :
- European Journal of Investigation in Health, Psychology and Education
- Accession number :
- edsair.doi.dedup.....63c85d9a42fdb950bdaddc74583ccf1c
- Full Text :
- https://doi.org/10.3390/ejihpe10010029