Back to Search Start Over

Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

Authors :
Peter Bossew
Emilija Ivanovska Janevik
Vaso Taleski
Zora S. Zunic
Mimoza Ristova
Sorsa Ajka
Kremena Ivanova
Martina Tsenova
Zdenka Stojanovska
Blazo Boev
Source :
Radiation and Environmental Biophysics
Publication Year :
2016
Publisher :
Springer, 2016.

Abstract

Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m(3) for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.

Details

Database :
OpenAIRE
Journal :
Radiation and Environmental Biophysics
Accession number :
edsair.doi.dedup.....6354624daa509be2a7be9c537422fbb3