Back to Search
Start Over
Phantom criteria for qualification of brain FDG and amyloid PET across different cameras
- Source :
- EJNMMI Physics
- Publication Year :
- 2016
- Publisher :
- Springer Science and Business Media LLC, 2016.
-
Abstract
- Background While fluorodeoxyglucose (FDG) and amyloid PET is valuable for patient management, research, and clinical trial of therapeutics on Alzheimer’s disease, the specific details of the PET scanning method including the PET camera model type influence the image quality, which may further affect the interpretation of images and quantitative capabilities. To make multicenter PET data reliable and to establish PET scanning as a universal diagnostic technique and a verified biomarker, we have proposed phantom test procedures and criteria for optimizing image quality across different PET cameras. Results As the method, four physical parameters (resolution, gray-white contrast, uniformity, and image noise) were selected as essential to image quality for brain FDG and amyloid PET and were measured with a Hoffman 3D brain phantom and a uniform cylindrical phantom on a total of 12 currently used PET models. The phantom radioactivity and acquisition time were determined based on the standard scanning protocol for each PET drug (FDG, 11C-PiB, 18F-florbetapir, and 18F-flutemetamol). Reconstruction parameters were either determined based on the methods adopted in ADNI, J-ADNI, and other research and clinical trials or optimized based on measured phantom image parameters under various reconstruction conditions. As the result, phantom test criteria were proposed as follows: (i) 8 mm FWHM or better resolution and (ii) gray/white %contrast ≥55 % with the Hoffman 3D brain phantom and (iii) SD of 51 small region of interests (ROIs) ≤0.0249 (equivalent to 5 % variation) for uniformity and (iv) image noise (SD/mean) ≤15 % for a large ROI with the uniform cylindrical phantom. These criteria provided image quality conforming to those multicenter clinical studies and were also achievable with most of the PET cameras that are currently used. Conclusions The proposed phantom test criteria facilitate standardization and qualification of brain FDG and amyloid PET images and deserve further evaluation by future multicenter clinical studies.
- Subjects :
- Image quality
Biomedical Engineering
Amyloid pet
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
medicine
Image noise
Radiology, Nuclear Medicine and imaging
Instrumentation
Original Research
Fluorodeoxyglucose
Radiation
Test procedures
business.industry
Multicenter study
Standardization
Patient management
Amyloid PET
Acquisition time
Brain FDG-PET
Nuclear medicine
business
030217 neurology & neurosurgery
medicine.drug
Subjects
Details
- ISSN :
- 21977364
- Volume :
- 3
- Database :
- OpenAIRE
- Journal :
- EJNMMI Physics
- Accession number :
- edsair.doi.dedup.....6341cf42027d835d5e5538bbb1ef99bf
- Full Text :
- https://doi.org/10.1186/s40658-016-0159-y