Back to Search
Start Over
Intraoperative Fragmentation and Retention of Endovascular Devices: Clinical Consequences and Preventative Strategies
- Source :
- Vascular and Endovascular Surgery. 54:118-125
- Publication Year :
- 2019
- Publisher :
- SAGE Publications, 2019.
-
Abstract
- Background: Expanded applications and increasing volumes of complex endovascular procedures have increased the risk of unintended intraoperative fragmentation and retention of catheters and sheaths. We describe a series of retained or fragmented endovascular devices, a quality improvement program to address this unmet need for improved detection of catheter fragmentation, and the results of this program. Methods: Cases utilizing endovascular devices that resulted in a retained catheter fragment were identified and analyzed during divisional quality improvement review. One consistent area of concern was operating room (OR) staff unfamiliarity with verifying the integrity of an endovascular device. In response, a slide-based training protocol of focused, endovascular nursing education was implemented. Following perceived lack of improvement after this approach, we developed a handheld visual reference display of the tips of common catheters and sheaths. Staff was surveyed before and after intervention to assess the educational value of the display and the impact on staff device familiarity. Results: All 4 described cases resulted in an unplanned return to the OR for retrieval of the fragmented catheter or sheath. No thromboembolic complications were observed, although associated intra-arterial thrombus was noted in 2 cases. Thirty-four OR nurses were polled to trial the visual reference display initiative, with 70% of those reporting primary surgical assignments outside of cardiovascular ORs. Introduction of the new visual reference display improved staff confidence in their ability to identify a broken device (2.4-3.7, P < .001). This improvement was most significant in OR staff with primary assignments in noncardiovascular services. Conclusion: Current OR standard operating procedures fail to address the potential for unintentionally retained catheters and wires during endovascular procedures. Our novel visual reference display of common endovascular items rather than conventional in-service training improved the ability of staff to identify device fragmentation at the time of the index procedure.
- Subjects :
- Adult
Male
Reoperation
Health Knowledge, Attitudes, Practice
medicine.medical_specialty
Attitude of Health Personnel
Retained foreign body
Nursing Staff, Hospital
030204 cardiovascular system & hematology
Operating Room Nursing
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Humans
Medicine
Intensive care medicine
Device Removal
Aged
business.industry
Endovascular Procedures
Fragmentation (computing)
Equipment Design
General Medicine
Middle Aged
Foreign Bodies
Treatment Outcome
Equipment Failure
Female
Surgery
Clinical Competence
Cardiology and Cardiovascular Medicine
business
Vascular Access Devices
Subjects
Details
- ISSN :
- 19389116 and 15385744
- Volume :
- 54
- Database :
- OpenAIRE
- Journal :
- Vascular and Endovascular Surgery
- Accession number :
- edsair.doi.dedup.....61fc292edbe55c28ec6e04e3c1ddd321