Back to Search Start Over

Monolithic zirconia single tooth implant‐supported restorations with <scp>CAD</scp> / <scp>CAM</scp> titanium abutments in the posterior region: A 1‐year prospective case series study

Authors :
Vincent J. J. Donker
Gerry M. Raghoebar
Charlotte Jensen‐Louwerse
Arjan Vissink
Henny J. A. Meijer
Personalized Healthcare Technology (PHT)
Man, Biomaterials and Microbes (MBM)
Translational Immunology Groningen (TRIGR)
Source :
Clinical Implant Dentistry and Related Research, 125-132. Wiley, ISSUE=1;STARTPAGE=125;ENDPAGE=132;ISSN=1523-0899;TITLE=Clinical Implant Dentistry and Related Research
Publication Year :
2022
Publisher :
Wiley, 2022.

Abstract

PURPOSE: To assess the clinical, radiographic, and patient-reported outcome measures, including the success of screw-retained monolithic zirconia implant-supported restorations with CAD/CAM titanium abutments in the posterior region during a 1-year follow-up.METHODS: In a prospective case series, 50 molar sites in the posterior region of 46 patients with a minimum age of 18 years and sufficient bone volume and anatomical conditions for placing an implant (≥8 mm) and an anatomical restoration were included. Parallel-walled implants with a conical connection were inserted in a two-stage surgical procedure. Implant uncovering and healing abutment placement occurred 12 weeks after insertion. Two weeks after mucosa healing, a screw-retained monolithic zirconia restoration with a CAD/CAM titanium abutment was placed. Clinical, radiographic, and patient-reported outcome measures were collected at baseline before implant placement and then during the 1 month and 1 year follow-ups.RESULTS: At the 1 year follow-up, 49 restorations could be evaluated. The plaque accumulation, presence of calculus, bleeding tendency and peri-implant inflammation indices were low, representing healthy peri-implant conditions. The mean marginal bone level change between the 1 month and the 1 year follow-up was -0.17 &#177; 0.46 mm. The mean patient satisfaction was high. The restoration success was, according to the modified USPHS criteria, 95.9%.CONCLUSION: Monolithic zirconia implant-supported restorations with CAD/CAM titanium abutments have very good clinical, radiographic and patient-reported outcomes after 1 year in function.

Details

ISSN :
17088208 and 15230899
Volume :
24
Database :
OpenAIRE
Journal :
Clinical Implant Dentistry and Related Research
Accession number :
edsair.doi.dedup.....6128108ac892093cc780a9505ade5590